Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1995 |
Principal Product | Wooden Pallets |
NAICS | n/a |
SIC | 2448 - Wood Pallets And Skids |
Sales | $5,000,000-$10,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 9,000 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 4,498 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $86,573 | 761,137 | kWh | $0.11 |
TOTAL ENERGY COSTS | $86,573 | |||
RECOMMENDED SAVINGS* | $19,475 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,366 |
#|Description |
Savings Cost |
Status | Electricity Usage | Fuel Oil #2 | Personnel Changes | Administrative Changes | Electricity Usage | Fuel Oil #2 | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $5,541 Cost: $1,000 |
$5,541 | - | - | - | - | - | - | - |
$5,541 - kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $4,588 Cost: $84 |
- | - | - | - | $4,588 | - | - | - |
- - kWh |
- - MMBtu |
$4,588 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $972 Cost: $3,690 |
$972 | 9,379 | - | - | - | - | - | - |
$972 9,379 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,911 Cost: $5,465 |
$1,911 | 19,930 | - | - | - | - | - | - |
$1,911 19,930 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $895 Cost: $1,800 |
$895 | 13,482 | - | - | - | - | - | - |
$895 13,482 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4134 REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE |
Savings: $5,568 Cost: $27,500 |
$15,848 | 137,163 | $(-7,280) | (-2,038) | - | - | $(-3,000) | - |
$15,848 137,163 kWh |
$(-7,280) (-2,038) MMBtu |
- - $ |
$(-3,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,475 Cost: $39,539 |
$25,167 | 179,954 | $(-7,280) | (-2,038) | $4,588 | - | $(-3,000) | - | $25,167 179,954 kWh |
$(-7,280) (-2,038) MMBtu |
$4,588 - $ |
$(-3,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,366 Cost: $11,039 |
$3,778 | 42,791 | - | - | $4,588 | - | - | - | $3,778 42,791 kWh |
- - MMBtu |
$4,588 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Fuel Oil #2 | Personnel Changes | Administrative Changes | Electricity Usage | Fuel Oil #2 | Personnel Changes | Administrative Changes |