Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1996 |
Principal Product | Animal Feed |
NAICS | n/a |
SIC | 2048 - Prepared Feeds, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 30,000 Tons |
Production Hrs. Annual | 4,160 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,707 | 1,247,362 | kWh | $0.05 |
Electricity Demand | $52,963 | 5,180 | kW-months/year | $10.22 |
Natural Gas | $8,927 | 1,710 | MMBtu | $5.22 |
TOTAL ENERGY COSTS | $125,597 | |||
RECOMMENDED SAVINGS* | $95,558 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,549 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,468 Cost: $2,440 |
$1,012 | 19,930 | $456 | 66 | - | - | - | - | - | - | - | - | - | - |
$1,012 19,930 kWh |
$456 66 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $81 Cost: $444 |
$81 | 4,396 | - | - | - | - | - | - | - | - | - | - | - | - |
$81 4,396 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $16,942 Cost: $15,758 |
- | - | - | - | $16,942 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$16,942 - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $707 Cost: $(-7,300) |
$507 | 9,965 | $200 | 29 | - | - | - | - | - | - | - | - | - | - |
$507 9,965 kWh |
$200 29 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $76,086 Cost: $125,114 |
$(-2,473) | (-26,377) | - | - | - | - | $32,880 | - | - | - | $3,679 | - | $42,000 | - |
$(-2,473) (-26,377) kWh |
- - kW-months/year |
- - $ |
$32,880 - $ |
- - $ |
$3,679 - $ |
$42,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $274 Cost: - |
- | - | - | - | - | - | - | - | $274 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$274 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $95,558 Cost: $136,456 |
$(-873) | 7,914 | $656 | 95 | $16,942 | - | $32,880 | - | $274 | - | $3,679 | - | $42,000 | - | $(-873) 7,914 kWh |
$656 95 kW-months/year |
$16,942 - $ |
$32,880 - $ |
$274 - $ |
$3,679 - $ |
$42,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,549 Cost: $2,884 |
$1,093 | 24,326 | $456 | 66 | - | - | - | - | - | - | - | - | - | - | $1,093 24,326 kWh |
$456 66 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product |