Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2022 |
Principal Product | Water Pumps |
NAICS | 333996 - Fluid Power Pump and Motor Manufacturing |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 466,864 |
Annual Production | 4,754 Units |
Production Hrs. Annual | 2,080 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $26,828 | 486,533 | kWh | $0.06 |
Electricity Demand | $21,912 | 2,003 | kW-months/year | $10.94 |
Electricity Fees | $10,768 | - | $ | - |
Natural Gas | $1,071 | 120 | MMBtu | $8.95 |
LPG | $7,351 | 209 | MMBtu | $35.12 |
Fuel Oil #1 | $33,633 | 1,806 | MMBtu | $18.62 |
TOTAL ENERGY COSTS | $117,163 | |||
RECOMMENDED SAVINGS* | $54,730 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $48,913 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #1 | Solid Waste (non-haz) | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Fuel Oil #1 | Solid Waste (non-haz) | Ancillary Material Cost | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $5,354 Cost: $640 |
$2,739 | 49,804 | $2,615 | 239 | - | - | - | - | - | - | - | - |
$2,739 49,804 kWh |
$2,615 239 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $3,407 Cost: $2,618 |
$1,873 | 34,057 | $1,534 | 140 | - | - | - | - | - | - | - | - |
$1,873 34,057 kWh |
$1,534 140 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6242 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION |
Savings: $3,363 Cost: - |
- | - | - | - | $3,363 | 181 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,363 181 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,190 Cost: $15,730 |
$1,632 | 29,679 | $1,558 | 142 | - | - | - | - | - | - | - | - |
$1,632 29,679 kWh |
$1,558 142 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,991 Cost: $304 |
$1,991 | 36,200 | - | - | - | - | - | - | - | - | - | - |
$1,991 36,200 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,972 Cost: - |
$1,972 | 35,862 | - | - | - | - | - | - | - | - | - | - |
$1,972 35,862 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $1,440 Cost: $3,987 |
$802 | 14,580 | $638 | 58 | - | - | - | - | - | - | - | - |
$802 14,580 kWh |
$638 58 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,187 Cost: $4,373 |
$1,187 | 21,577 | - | - | - | - | - | - | - | - | - | - |
$1,187 21,577 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $1,049 Cost: $200 |
$1,049 | 19,078 | - | - | - | - | - | - | - | - | - | - |
$1,049 19,078 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.311 SCHEDULE DELIVERIES ACCORDING TO DEMAND |
Savings: $3,120 Cost: $2,528 |
- | - | - | - | - | - | - | - | $3,120 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$3,120 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $28,657 Cost: $31,000 |
$(-386) | (-7,020) | $(-5,907) | (-540) | - | - | $15,600 | 915,931 | - | - | $19,349 | - |
$(-386) (-7,020) kWh |
$(-5,907) (-540) kW-months/year |
- - MMBtu |
$15,600 915,931 lb |
- - $ |
$19,349 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $54,730 Cost: $61,380 |
$12,859 | 233,817 | $439 | 40 | $3,363 | 181 | $15,600 | 915,931 | $3,120 | - | $19,349 | - | $12,859 233,817 kWh |
$439 40 kW-months/year |
$3,363 181 MMBtu |
$15,600 915,931 lb |
$3,120 - $ |
$19,349 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $48,913 Cost: $37,290 |
$9,238 | 167,981 | $(-1,757) | (-161) | $3,363 | 181 | $15,600 | 915,931 | $3,120 | - | $19,349 | - | $9,238 167,981 kWh |
$(-1,757) (-161) kW-months/year |
$3,363 181 MMBtu |
$15,600 915,931 lb |
$3,120 - $ |
$19,349 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #1 | Solid Waste (non-haz) | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Fuel Oil #1 | Solid Waste (non-haz) | Ancillary Material Cost | By-product Production |