Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2022 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $1,000,000-$5,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 1,314,968 |
Annual Production | 2,900,770 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $476,429 | 5,642,949 | kWh | $0.08 |
Electricity Demand | $49,718 | 16,409 | kW-months/year | $3.03 |
Electricity Fees | $47,566 | - | $ | - |
TOTAL ENERGY COSTS | $573,713 | |||
RECOMMENDED SAVINGS* | $705,047 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $649,622 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $42,152 Cost: $105,185 |
$34,131 | 406,324 | $8,021 | 2,647 | - | - | - | - | - | - |
$34,131 406,324 kWh |
$8,021 2,647 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $36,661 Cost: $30,359 |
$33,181 | 395,006 | $3,480 | 1,148 | - | - | - | - | - | - |
$33,181 395,006 kWh |
$3,480 1,148 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $13,557 Cost: $36,000 |
$13,557 | 161,394 | - | - | - | - | - | - | - | - |
$13,557 161,394 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $5,945 Cost: $25,600 |
$5,945 | 70,776 | - | - | - | - | - | - | - | - |
$5,945 70,776 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,294 Cost: $10,558 |
$5,294 | 63,024 | - | - | - | - | - | - | - | - |
$5,294 63,024 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,095 Cost: $12,753 |
$4,637 | 55,202 | $458 | 151 | - | - | - | - | - | - |
$4,637 55,202 kWh |
$458 151 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,079 Cost: $5,093 |
- | - | - | - | - | - | $2,079 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,079 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,003 Cost: - |
$2,003 | 18,373 | - | - | - | - | - | - | - | - |
$2,003 18,373 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.661 LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT |
Savings: $47,401 Cost: $10,000 |
$47,401 | 564,295 | - | - | - | - | - | - | - | - |
$47,401 564,295 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $4,716 Cost: - |
- | - | - | - | - | - | $4,716 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,716 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $540,144 Cost: $53,000 |
$(-26,711) | (-317,988) | $(-1,320) | (-436) | $(-28,148) | (-2,100) | - | - | $596,323 | - |
$(-26,711) (-317,988) kWh |
$(-1,320) (-436) kW-months/year |
$(-28,148) (-2,100) MMBtu |
- - $ |
$596,323 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $705,047 Cost: $288,548 |
$119,438 | 1,416,406 | $10,639 | 3,511 | $(-28,148) | (-2,100) | $6,795 | - | $596,323 | - | $119,438 1,416,406 kWh |
$10,639 3,511 kW-months/year |
$(-28,148) (-2,100) MMBtu |
$6,795 - $ |
$596,323 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $649,622 Cost: $247,855 |
$66,092 | 781,335 | $10,639 | 3,511 | $(-28,148) | (-2,100) | $4,716 | - | $596,323 | - | $66,092 781,335 kWh |
$10,639 3,511 kW-months/year |
$(-28,148) (-2,100) MMBtu |
$4,716 - $ |
$596,323 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | By-product Production |