Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2022 |
Principal Product | Cement |
NAICS | 327310 - Cement Manufacturing |
SIC | 3241 - Cement, Hydraulic |
Sales | $100,000,000-$500,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 2,940,500 |
Annual Production | 1,406,896 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $6,367,017 | 120,383,345 | kWh | $0.05 |
Electricity Demand | $861,386 | 209,171 | kW-months/year | $4.12 |
Electricity Fees | $532,698 | - | $ | - |
Natural Gas | $5,496,387 | 1,150,881 | MMBtu | $4.78 |
TOTAL ENERGY COSTS | $13,257,488 | |||
RECOMMENDED SAVINGS* | $5,965,518 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $636,360 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $3,357,648 Cost: $12,825,000 |
$4,505,000 | 85,000,000 | $494,160 | 120,000 | $(-791,512) | (-497,178) | - | - | $(-850,000) | - |
$4,505,000 85,000,000 kWh |
$494,160 120,000 kW-months/year |
$(-791,512) (-497,178) MMBtu |
- - $ |
$(-850,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,189,637 Cost: $2,090,000 |
$780,464 | 14,725,728 | $101,068 | 24,540 | $308,105 | 64,511 | - | - | - | - |
$780,464 14,725,728 kWh |
$101,068 24,540 kW-months/year |
$308,105 64,511 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $506,910 Cost: $647,662 |
$446,622 | 8,426,834 | $60,288 | 14,640 | - | - | - | - | - | - |
$446,622 8,426,834 kWh |
$60,288 14,640 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $226,296 Cost: $102,253 |
$197,058 | 3,718,082 | $29,238 | 7,100 | - | - | - | - | - | - |
$197,058 3,718,082 kWh |
$29,238 7,100 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2428 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC |
Savings: $207,860 Cost: $705,580 |
$(-17,080) | (-322,272) | $(-2,211) | (-537) | $227,151 | 47,561 | - | - | - | - |
$(-17,080) (-322,272) kWh |
$(-2,211) (-537) kW-months/year |
$227,151 47,561 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $37,793 Cost: $79,204 |
$31,478 | 593,928 | $6,315 | 1,534 | - | - | - | - | - | - |
$31,478 593,928 kWh |
$6,315 1,534 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2623 MINIMIZE CONDENSER COOLING WATER TEMPERATURE |
Savings: $32,856 Cost: $29,990 |
$32,856 | 619,920 | - | - | - | - | - | - | - | - |
$32,856 619,920 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $22,408 Cost: $756 |
$22,408 | 422,794 | - | - | - | - | - | - | - | - |
$22,408 422,794 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $19,379 Cost: - |
$19,379 | 365,638 | - | - | - | - | - | - | - | - |
$19,379 365,638 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $16,853 Cost: $7,275 |
$16,853 | 317,988 | - | - | - | - | - | - | - | - |
$16,853 317,988 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $14,868 Cost: $12,700 |
$(-1,339) | (-25,272) | $(-173) | (-42) | - | - | $16,380 | - | - | - |
$(-1,339) (-25,272) kWh |
$(-173) (-42) kW-months/year |
- - MMBtu |
$16,380 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $333,010 Cost: - |
- | - | - | - | - | - | - | - | $333,010 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$333,010 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $5,965,518 Cost: $16,500,420 |
$6,033,699 | 113,843,368 | $688,685 | 167,235 | $(-256,256) | (-385,106) | $16,380 | - | $(-516,990) | - | $6,033,699 113,843,368 kWh |
$688,685 167,235 kW-months/year |
$(-256,256) (-385,106) MMBtu |
$16,380 - $ |
$(-516,990) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $636,360 Cost: $189,488 |
$267,797 | 5,052,792 | $35,553 | 8,634 | - | - | - | - | $333,010 | - | $267,797 5,052,792 kWh |
$35,553 8,634 kW-months/year |
- - MMBtu |
- - $ |
$333,010 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes |