Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2023
Principal Product Personal Care Products
NAICS 325620 - Toilet Preparation Manufacturing
SIC 2844 - Toilet Preparations
Sales $10,000,000-$50,000,000
# of Employees 35
Plant Area (Sq.Ft.) 190,000
Annual Production 106,863,526 Units
Production Hrs. Annual 6,240
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $385,672 6,405,136 kWh $0.06
Electricity Demand $227,953 15,753 kW-months/year $14.47
Electricity Fees $100,456 - $ -
Natural Gas $186,251 26,700 MMBtu $6.98
TOTAL ENERGY COSTS $900,332
RECOMMENDED SAVINGS* $276,705 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $151,814
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$94,792
Cost:
$289,896
$39,227 653,776 $55,565 3,840 - - - - $39,227
653,776
kWh
$55,565
3,840
kW-months/year
-
-
MMBtu
-
-
$
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$61,221
Cost:
$34,460
$38,431 640,514 $22,790 1,575 - - - - $38,431
640,514
kWh
$22,790
1,575
kW-months/year
-
-
MMBtu
-
-
$
03: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL Savings:
$30,832
Cost:
$8,310
$(-300) (-5,000) $(-868) (-60) - - $32,000 - $(-300)
(-5,000)
kWh
$(-868)
(-60)
kW-months/year
-
-
MMBtu
$32,000
-
$
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$26,906
Cost:
$25,280
$26,906 448,737 - - - - - - $26,906
448,737
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$19,433
Cost:
$14,328
$11,944 199,064 $7,489 518 - - - - $11,944
199,064
kWh
$7,489
518
kW-months/year
-
-
MMBtu
-
-
$
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$10,556
Cost:
$22,000
$7,338 122,298 $3,218 222 - - - - $7,338
122,298
kWh
$3,218
222
kW-months/year
-
-
MMBtu
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,338
Cost:
$432
$9,338 155,628 - - - - - - $9,338
155,628
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
08: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT Savings:
$8,114
Cost:
-
$8,114 135,241 - - - - - - $8,114
135,241
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
09: 2.1222 INSTALL TURBULATORS Savings:
$6,732
Cost:
$7,500
- - - - $6,732 965 - - -
-
kWh
-
-
kW-months/year
$6,732
965
MMBtu
-
-
$
10: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM Savings:
$5,588
Cost:
$2,800
- - - - $5,588 801 - - -
-
kWh
-
-
kW-months/year
$5,588
801
MMBtu
-
-
$
11: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$3,193
Cost:
$15,120
$3,193 53,217 - - - - - - $3,193
53,217
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$276,705
Cost:
$420,126
$144,191 2,403,475 $88,194 6,095 $12,320 1,766 $32,000 - $144,191
2,403,475
kWh
$88,194
6,095
kW-months/year
$12,320
1,766
MMBtu
$32,000
-
$
TOTAL IMPLEMENTED Savings:
$151,814
Cost:
$89,830
$74,865 1,247,745 $32,629 2,255 $12,320 1,766 $32,000 - $74,865
1,247,745
kWh
$32,629
2,255
kW-months/year
$12,320
1,766
MMBtu
$32,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes