Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2024 |
Principal Product | Rigid Packaging |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 1,700,000,000 Units |
Production Hrs. Annual | 3,276 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $277,369 | 7,769,113 | kWh | $0.04 |
Electricity Demand | $230,294 | 34,581 | kW-months/year | $6.66 |
Electricity Fees | $536,824 | - | $ | - |
Natural Gas | $4,481 | 330 | MMBtu | $13.56 |
TOTAL ENERGY COSTS | $1,080,435 | |||
RECOMMENDED SAVINGS* | $215,322 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $50,241 Cost: $322,608 |
$24,667 | 685,184 | $25,574 | 3,840 | - | - |
$24,667 685,184 kWh |
$25,574 3,840 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $35,722 Cost: $41,798 |
$19,578 | 543,838 | $16,144 | 2,424 | - | - |
$19,578 543,838 kWh |
$16,144 2,424 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $24,631 Cost: $18,563 |
$(-427) | (-11,848) | $(-421) | (-63) | $25,479 | - |
$(-427) (-11,848) kWh |
$(-421) (-63) kW-months/year |
$25,479 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $19,913 Cost: $25,350 |
$19,913 | 553,135 | - | - | - | - |
$19,913 553,135 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $15,952 Cost: $39,000 |
$6,442 | 178,936 | $9,510 | 1,428 | - | - |
$6,442 178,936 kWh |
$9,510 1,428 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,910 Cost: $351 |
$6,910 | 191,931 | - | - | - | - |
$6,910 191,931 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $6,473 Cost: $24,140 |
$6,473 | 179,801 | - | - | - | - |
$6,473 179,801 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $4,230 Cost: $12,000 |
$4,230 | 117,495 | - | - | - | - |
$4,230 117,495 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4325 UPGRADE CONVEYORS |
Savings: $3,290 Cost: $8,838 |
$3,290 | 91,385 | - | - | - | - |
$3,290 91,385 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE |
Savings: $2,337 Cost: $1,797 |
$2,337 | 64,916 | - | - | - | - |
$2,337 64,916 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $1,889 Cost: $8,355 |
$1,889 | 52,463 | - | - | - | - |
$1,889 52,463 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $10,444 Cost: $4,280 |
- | - | - | - | $10,444 | - |
- - kWh |
- - kW-months/year |
$10,444 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.661 LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT |
Savings: $27,969 Cost: $60,000 |
$27,969 | 776,911 | - | - | - | - |
$27,969 776,911 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $5,321 Cost: $3,260 |
$5,321 | 171,177 | - | - | - | - |
$5,321 171,177 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $215,322 Cost: $570,340 |
$128,592 | 3,595,324 | $50,807 | 7,629 | $35,923 | - | $128,592 3,595,324 kWh |
$50,807 7,629 kW-months/year |
$35,923 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes |