Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Ice Making Machines |
NAICS | n/a |
SIC | 3443 - Fabricated Plate Work (boiler Shops) |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 406 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $199,462 | 7,856,682 | kWh | $0.03 |
Electricity Demand | $175,563 | 24,936 | kW-months/year | $7.04 |
Natural Gas | $31,944 | 24,570 | MMBtu | $1.30 |
TOTAL ENERGY COSTS | $411,329 | |||
RECOMMENDED SAVINGS* | $7,422 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $248 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $248 Cost: $9,180 |
$93 | 3,810 | $155 | 22 | - | - | - | - | - | - |
$93 3,810 kWh |
$155 22 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $997 Cost: $3,214 |
$365 | 14,361 | $632 | 90 | - | - | - | - | - | - |
$365 14,361 kWh |
$632 90 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,268 Cost: $100 |
$684 | 26,964 | $584 | 83 | - | - | - | - | - | - |
$684 26,964 kWh |
$584 83 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $694 Cost: $20 |
$379 | 14,947 | $315 | 45 | - | - | - | - | - | - |
$379 14,947 kWh |
$315 45 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7494 INSTALL STORM WINDOWS AND DOORS |
Savings: $1,928 Cost: $2,000 |
$311 | 12,309 | $196 | 29 | $1,421 | 1,119 | - | - | - | - |
$311 12,309 kWh |
$196 29 kW-months/year |
$1,421 1,119 MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5221 RECYCLE CASTING SAND |
Savings: $151 Cost: - |
- | - | - | - | - | - | - | - | $151 | 194,400 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$151 194,400 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $2,136 Cost: - |
- | - | - | - | - | - | $2,136 | 120 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,136 120 gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,422 Cost: $14,514 |
$1,832 | 72,391 | $1,882 | 269 | $1,421 | 1,119 | $2,136 | 120 | $151 | 194,400 | $1,832 72,391 kWh |
$1,882 269 kW-months/year |
$1,421 1,119 MMBtu |
$2,136 120 gal |
$151 194,400 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $248 Cost: $9,180 |
$93 | 3,810 | $155 | 22 | - | - | - | - | - | - | $93 3,810 kWh |
$155 22 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) |