Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1997 |
Principal Product | Lithographic Printing |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 62,000 |
Annual Production | 20,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $65,000 | 2,489,449 | kWh | $0.03 |
Electricity Demand | $58,532 | 6,282 | kW-months/year | $9.32 |
Natural Gas | $8,785 | 2,103 | MMBtu | $4.18 |
TOTAL ENERGY COSTS | $135,749 | |||
RECOMMENDED SAVINGS* | $49,341 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $158 Cost: $2,560 |
$101 | 3,810 | $57 | 6 | - | - | - | - | - | - | - | - |
$101 3,810 kWh |
$57 6 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $532 Cost: $970 |
$345 | 13,189 | $187 | 20 | - | - | - | - | - | - | - | - |
$345 13,189 kWh |
$187 20 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $255 Cost: $20 |
$119 | 4,689 | $136 | 15 | - | - | - | - | - | - | - | - |
$119 4,689 kWh |
$136 15 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $135 Cost: $87 |
$85 | 3,224 | $50 | 5 | - | - | - | - | - | - | - | - |
$85 3,224 kWh |
$50 5 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $679 Cost: $400 |
- | - | - | - | $679 | 165 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$679 165 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $26,400 Cost: - |
- | - | - | - | - | - | - | - | $26,400 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$26,400 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.8143 RECYCLE CLEANING SOLVENT AND REUSE |
Savings: $4,260 Cost: $9,226 |
- | - | - | - | - | - | - | - | - | - | $4,260 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$4,260 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $16,922 Cost: - |
- | - | - | - | - | - | $322 | 1,413 | $16,600 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$322 1,413 gal |
$16,600 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,341 Cost: $13,263 |
$650 | 24,912 | $430 | 46 | $679 | 165 | $322 | 1,413 | $43,000 | - | $4,260 | - | $650 24,912 kWh |
$430 46 kW-months/year |
$679 165 MMBtu |
$322 1,413 gal |
$43,000 - $ |
$4,260 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Primary Raw Material | Ancillary Material Cost |