Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 1994
Principal Product Pickling and slitting
NAICS n/a
SIC 3399 - Primary Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 250,000
Annual Production 600,000 Tons
Production Hrs. Annual 8,400
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Natural Gas $312,215 117,773 MMBtu $2.65
TOTAL ENERGY COSTS $312,215
RECOMMENDED SAVINGS* $33,224 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $32,811
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$12,087
Cost:
$19,430
- - $12,087 4,578 -
-
kWh
$12,087
4,578
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$11,226
Cost:
$15,513
- - $11,226 4,252 -
-
kWh
$11,226
4,252
MMBtu
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$4,498
Cost:
$16,200
- - $4,498 1,704 -
-
kWh
$4,498
1,704
MMBtu
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,000
Cost:
-
$5,000 - - - $5,000
-
kWh
-
-
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$413
Cost:
$350
- - $413 156 -
-
kWh
$413
156
MMBtu
TOTAL RECOMMENDED Savings:
$33,224
Cost:
$51,493
$5,000 - $28,224 10,690 $5,000
-
kWh
$28,224
10,690
MMBtu
TOTAL IMPLEMENTED Savings:
$32,811
Cost:
$51,143
$5,000 - $27,811 10,534 $5,000
-
kWh
$27,811
10,534
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas