Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Washington |
---|---|
Assessment Year | 2023 |
Principal Product | Warm Mix and Hot Mix Asphalt |
NAICS | 327320 - Ready-Mix Concrete Manufacturing |
SIC | 3273 - Ready-mixed Concrete |
Sales | $10,000,000-$50,000,000 |
# of Employees | 8 |
Plant Area (Sq.Ft.) | 61,828 |
Annual Production | 250,000 Tons |
Production Hrs. Annual | 2,340 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $88,580 | 1,088,833 | kWh | $0.08 |
Electricity Demand | $23,226 | 6,082 | kW-months/year | $3.82 |
Electricity Fees | $1,186 | - | $ | - |
Natural Gas | $239,436 | 40,724 | MMBtu | $5.88 |
TOTAL ENERGY COSTS | $352,428 | |||
RECOMMENDED SAVINGS* | $86,587 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $86,587 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,223 Cost: - |
$986 | 12,123 | $237 | 62 | - | - |
$986 12,123 kWh |
$237 62 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $491 Cost: $1,096 |
$491 | 6,031 | - | - | - | - |
$491 6,031 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7494 INSTALL STORM WINDOWS AND DOORS |
Savings: $145 Cost: $1,901 |
$134 | 1,647 | $11 | 3 | - | - |
$134 1,647 kWh |
$11 3 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $206 Cost: $1,815 |
$152 | 1,866 | $54 | 14 | - | - |
$152 1,866 kWh |
$54 14 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $47,887 Cost: $200,000 |
- | - | - | - | $47,887 | 8,145 |
- - kWh |
- - kW-months/year |
$47,887 8,145 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $36,635 Cost: - |
- | - | - | - | $36,635 | 6,231 |
- - kWh |
- - kW-months/year |
$36,635 6,231 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $86,587 Cost: $204,812 |
$1,763 | 21,667 | $302 | 79 | $84,522 | 14,376 | $1,763 21,667 kWh |
$302 79 kW-months/year |
$84,522 14,376 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $86,587 Cost: $204,812 |
$1,763 | 21,667 | $302 | 79 | $84,522 | 14,376 | $1,763 21,667 kWh |
$302 79 kW-months/year |
$84,522 14,376 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |