Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1988
Principal Product MILK, ICE CREAM, CHEESE
NAICS n/a
SIC 2026 - Fluid Milk
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 5,500
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $472,194 6,735,932 kWh $0.07
Natural Gas $97,219 29,664 MMBtu $3.28
TOTAL ENERGY COSTS $569,413
RECOMMENDED SAVINGS* $38,247 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $21,956
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$5,607
Cost:
-
$5,607 80,012 - - - - $5,607
80,012
kWh
-
-
MMBtu
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,804
Cost:
-
$2,804 39,859 - - - - $2,804
39,859
kWh
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$687
Cost:
$417
$687 9,672 - - - - $687
9,672
kWh
-
-
MMBtu
-
-
$
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$894
Cost:
$500
$894 - - - - - $894
-
kWh
-
-
MMBtu
-
-
$
05: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$7,516
Cost:
$8,000
$7,516 107,268 - - - - $7,516
107,268
kWh
-
-
MMBtu
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$608
Cost:
$360
$608 8,792 - - - - $608
8,792
kWh
-
-
MMBtu
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,534
Cost:
$1,000
$1,534 21,981 - - - - $1,534
21,981
kWh
-
-
MMBtu
-
-
$
08: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$14,600
Cost:
-
$14,600 208,382 - - - - $14,600
208,382
kWh
-
-
MMBtu
-
-
$
09: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$2,248
Cost:
$700
- - $2,248 685 - - -
-
kWh
$2,248
685
MMBtu
-
-
$
10: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,749
Cost:
$250
- - $1,849 564 $(-100) - -
-
kWh
$1,849
564
MMBtu
$(-100)
-
$
TOTAL RECOMMENDED Savings:
$38,247
Cost:
$11,227
$34,250 475,966 $4,097 1,249 $(-100) - $34,250
475,966
kWh
$4,097
1,249
MMBtu
$(-100)
-
$
TOTAL IMPLEMENTED Savings:
$21,956
Cost:
$250
$20,207 288,394 $1,849 564 $(-100) - $20,207
288,394
kWh
$1,849
564
MMBtu
$(-100)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes