IAC logo
IAC Assessment: WI0172
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0172
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1993
Principal Product Heat Processing Furnaces
NAICS n/a
SIC 3567 - Industrial Furnaces And Ovens
Sales $10,000,000-$50,000,000
# of Employees 240
Plant Area (Sq.Ft.) 200,000
Annual Production 0 Units
Production Hrs. Annual 2,125
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $144,107 2,526,671 kWh $0.06
Natural Gas $40,865 10,862 MMBtu $3.76
TOTAL ENERGY COSTS $184,972
RECOMMENDED SAVINGS* $18,238 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,165
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.3133 CONSIDER THREE OR FOUR DAYS AROUND-THE-CLOCK OPERATION RATHER THAN ONE OR TWO SHIFTS PER DAY Savings:
$12,563
Cost:
-
$12,563 - - - $12,563
-
kWh
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,625
Cost:
$6,300
$2,257 39,566 $(-632) (-168) $2,257
39,566
kWh
$(-632)
(-168)
MMBtu
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,318
Cost:
$2,904
- - $1,318 351 -
-
kWh
$1,318
351
MMBtu
04: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$318
Cost:
$337
- - $318 85 -
-
kWh
$318
85
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$928
Cost:
$3,473
$928 16,413 - - $928
16,413
kWh
-
-
MMBtu
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$1,105
Cost:
$1,800
- - $1,105 294 -
-
kWh
$1,105
294
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$249
Cost:
-
$249 4,396 - - $249
4,396
kWh
-
-
MMBtu
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$132
Cost:
$640
$132 2,345 - - $132
2,345
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$18,238
Cost:
$15,454
$16,129 62,720 $2,109 562 $16,129
62,720
kWh
$2,109
562
MMBtu
TOTAL IMPLEMENTED Savings:
$2,165
Cost:
$5,913
$1,060 18,758 $1,105 294 $1,060
18,758
kWh
$1,105
294
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas