IAC logo
IAC Assessment: WI0179
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0179
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1993
Principal Product Process Control Valves
NAICS n/a
SIC 3492 - Fluid Power Valves & Hose Fittings
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 86,000
Annual Production 63,000 Pieces
Production Hrs. Annual 2,275
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $65,140 812,134 kWh $0.08
Natural Gas $9,719 3,224 MMBtu $3.01
TOTAL ENERGY COSTS $74,859
RECOMMENDED SAVINGS* $10,188 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,895
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$2,974
Cost:
$4,960
- - $2,974 845 -
-
kWh
$2,974
845
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,295
Cost:
$5,659
$2,295 28,722 - - $2,295
28,722
kWh
-
-
MMBtu
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,270
Cost:
-
$1,270 15,826 - - $1,270
15,826
kWh
-
-
MMBtu
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$1,354
Cost:
$2,800
$1,354 16,999 - - $1,354
16,999
kWh
-
-
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$776
Cost:
$500
- - $776 258 -
-
kWh
$776
258
MMBtu
06: 2.3133 CONSIDER THREE OR FOUR DAYS AROUND-THE-CLOCK OPERATION RATHER THAN ONE OR TWO SHIFTS PER DAY Savings:
$736
Cost:
-
$736 - - - $736
-
kWh
-
-
MMBtu
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$625
Cost:
$700
- - $625 208 -
-
kWh
$625
208
MMBtu
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$158
Cost:
$640
$158 2,052 - - $158
2,052
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$10,188
Cost:
$15,259
$5,813 63,599 $4,375 1,311 $5,813
63,599
kWh
$4,375
1,311
MMBtu
TOTAL IMPLEMENTED Savings:
$1,895
Cost:
$700
$1,270 15,826 $625 208 $1,270
15,826
kWh
$625
208
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas