IAC logo
IAC Assessment: WI0208
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0208
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1994
Principal Product Series universal motors of fractional horsepower for vacuum
NAICS n/a
SIC 3564 - Blowers And Fans
Sales $10,000,000-$50,000,000
# of Employees 600
Plant Area (Sq.Ft.) 210,000
Annual Production 4,200,000 Pieces
Production Hrs. Annual 6,600
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $417,574 8,369,578 kWh $0.05
Natural Gas $81,888 16,527 MMBtu $4.95
TOTAL ENERGY COSTS $499,462
RECOMMENDED SAVINGS* $47,375 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,158
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes
$ kWh $ MMBtu $ Tgal $ $
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$20,158
Cost:
-
- - - - - - $20,158 - -
-
kWh
-
-
MMBtu
-
-
Tgal
$20,158
-
$
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$8,821
Cost:
$15,000
$8,821 - - - - - - - $8,821
-
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$7,036
Cost:
$20,412
$7,036 - - - - - - - $7,036
-
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$5,198
Cost:
$12,000
$5,198 104,338 - - - - - - $5,198
104,338
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$335
Cost:
$329
- - $335 68 - - - - -
-
kWh
$335
68
MMBtu
-
-
Tgal
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$327
Cost:
$820
$327 6,448 - - - - - - $327
6,448
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
07: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE Savings:
$5,500
Cost:
$12,000
- - - - $5,500 18,000 - - -
-
kWh
-
-
MMBtu
$5,500
18,000
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$47,375
Cost:
$60,561
$21,382 110,786 $335 68 $5,500 18,000 $20,158 - $21,382
110,786
kWh
$335
68
MMBtu
$5,500
18,000
Tgal
$20,158
-
$
TOTAL IMPLEMENTED Savings:
$20,158
Cost:
-
- - - - - - $20,158 - -
-
kWh
-
-
MMBtu
-
-
Tgal
$20,158
-
$
Savings
Cost
$ kWh $ MMBtu $ Tgal $ $
Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes