IAC logo
IAC Assessment: WI0254
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0254
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1995
Principal Product Forgings (hand tools)
NAICS n/a
SIC 3423 - Hand And Edge Tools, Nec
Sales $5,000,000-$10,000,000
# of Employees 49
Plant Area (Sq.Ft.) 115,000
Annual Production 1,100 Tons
Production Hrs. Annual 2,100
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $111,051 1,282,532 kWh $0.09
Natural Gas $127,495 49,968 MMBtu $2.55
TOTAL ENERGY COSTS $240,285
RECOMMENDED SAVINGS* $11,606 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,981
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Electricity Usage Natural Gas Water Disposal
$ kWh $ MMBtu $ Tgal
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,254
Cost:
$270
$3,254 37,515 - - - - $3,254
37,515
kWh
-
-
MMBtu
-
-
Tgal
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$891
Cost:
$3,960
$891 10,258 - - - - $891
10,258
kWh
-
-
MMBtu
-
-
Tgal
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$470
Cost:
$909
$470 5,569 - - - - $470
5,569
kWh
-
-
MMBtu
-
-
Tgal
04: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$1,323
Cost:
$1,461
- - $1,323 519 - - -
-
kWh
$1,323
519
MMBtu
-
-
Tgal
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$764
Cost:
-
$764 8,792 - - - - $764
8,792
kWh
-
-
MMBtu
-
-
Tgal
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$404
Cost:
-
$404 - - - - - $404
-
kWh
-
-
MMBtu
-
-
Tgal
07: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER Savings:
$4,500
Cost:
$7,000
- - - - $4,500 4,900,000 -
-
kWh
-
-
MMBtu
$4,500
4,900,000
Tgal
TOTAL RECOMMENDED Savings:
$11,606
Cost:
$13,600
$5,783 62,134 $1,323 519 $4,500 4,900,000 $5,783
62,134
kWh
$1,323
519
MMBtu
$4,500
4,900,000
Tgal
TOTAL IMPLEMENTED Savings:
$4,981
Cost:
$1,731
$3,658 37,515 $1,323 519 - - $3,658
37,515
kWh
$1,323
519
MMBtu
-
-
Tgal
Savings
Cost
$ kWh $ MMBtu $ Tgal
Electricity Usage Natural Gas Water Disposal Electricity Usage Natural Gas Water Disposal