Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1996 |
Principal Product | Specialty Motors |
NAICS | n/a |
SIC | 3621 - Motors And Generators |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 500,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $213,121 | 8,615,768 | kWh | $0.02 |
Electricity Demand | $191,130 | 27,638 | kW-months/year | $6.92 |
Electricity Fees | $22,714 | - | $ | - |
Natural Gas | $238,833 | 71,742 | MMBtu | $3.33 |
TOTAL ENERGY COSTS | $716,984 | |||
RECOMMENDED SAVINGS* | $62,930 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,504 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $18,544 Cost: $3,400 |
- | - | - | - | $18,544 | 5,569 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$18,544 5,569 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $12,559 Cost: $30,000 |
$(-2,909) | (-111,958) | $(-1,732) | (-224) | - | - | $17,700 | 15,000,000 | - | - | $(-500) | - | - | - |
$(-2,909) (-111,958) kWh |
$(-1,732) (-224) kW-months/year |
- - MMBtu |
$17,700 15,000,000 Tgal |
- - lb |
$(-500) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $7,523 Cost: - |
- | - | $7,523 | 972 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$7,523 972 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $4,862 Cost: $27,740 |
$(-1,461) | (-56,272) | $(-1,118) | (-144) | $7,441 | 2,235 | - | - | - | - | - | - | - | - |
$(-1,461) (-56,272) kWh |
$(-1,118) (-144) kW-months/year |
$7,441 2,235 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $4,439 Cost: $1,000 |
- | - | - | - | - | - | - | - | $825 | - | - | - | $3,614 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$825 - lb |
- - $ |
$3,614 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $4,075 Cost: - |
$2,817 | 108,441 | $1,258 | 163 | - | - | - | - | - | - | - | - | - | - |
$2,817 108,441 kWh |
$1,258 163 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,216 Cost: $1,779 |
$1,529 | 58,910 | $687 | 89 | - | - | - | - | - | - | - | - | - | - |
$1,529 58,910 kWh |
$687 89 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $2,917 Cost: $9,000 |
$1,609 | 61,841 | $1,308 | 169 | - | - | - | - | - | - | - | - | - | - |
$1,609 61,841 kWh |
$1,308 169 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $2,700 Cost: - |
- | - | - | - | - | - | - | - | - | - | $2,700 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
$2,700 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,744 Cost: $15,000 |
$10,998 | 422,919 | $7,795 | 1,007 | $(-16,049) | (-4,820) | - | - | - | - | - | - | - | - |
$10,998 422,919 kWh |
$7,795 1,007 kW-months/year |
$(-16,049) (-4,820) MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7314 REDUCE VENTILATION AIR |
Savings: $351 Cost: $500 |
$194 | 7,327 | - | - | $157 | 47 | - | - | - | - | - | - | - | - |
$194 7,327 kWh |
- - kW-months/year |
$157 47 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $62,930 Cost: $88,419 |
$12,777 | 491,208 | $15,721 | 2,032 | $10,093 | 3,031 | $17,700 | 15,000,000 | $825 | - | $2,200 | - | $3,614 | - | $12,777 491,208 kWh |
$15,721 2,032 kW-months/year |
$10,093 3,031 MMBtu |
$17,700 15,000,000 Tgal |
$825 - lb |
$2,200 - $ |
$3,614 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,504 Cost: $30,019 |
$3,079 | 118,406 | $827 | 108 | $7,598 | 2,282 | - | - | - | - | - | - | - | - | $3,079 118,406 kWh |
$827 108 kW-months/year |
$7,598 2,282 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material |