Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1996 |
Principal Product | Micro electric circuitry, power supply, automotive, aerospac |
NAICS | n/a |
SIC | 3679 - Electronic Components, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 3,180,000 Pieces |
Production Hrs. Annual | 4,188 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $48,005 | 1,733,294 | kWh | $0.03 |
Electricity Demand | $33,611 | 3,841 | kW-months/year | $8.75 |
Electricity Fees | $4,175 | - | $ | - |
Natural Gas | $8,754 | 1,813 | MMBtu | $4.83 |
TOTAL ENERGY COSTS | $101,145 | |||
RECOMMENDED SAVINGS* | $283,502 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,786 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7314 REDUCE VENTILATION AIR |
Savings: $210,013 Cost: $64,100 |
$(-1,633) | (-56,272) | $(-123) | (-13) | $(-38,231) | (-7,915) | - | - | - | - | - | - | - | - | - | - | $250,000 | - |
$(-1,633) (-56,272) kWh |
$(-123) (-13) kW-months/year |
$(-38,231) (-7,915) MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
$250,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $60,000 Cost: $140,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $60,000 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
$60,000 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS |
Savings: $2,786 Cost: - |
$1,128 | 38,687 | $1,818 | 198 | - | - | - | - | - | - | - | - | $(-160) | - | - | - | - | - |
$1,128 38,687 kWh |
$1,818 198 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
$(-160) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $1,042 Cost: $3,100 |
$577 | 19,930 | $465 | 51 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$577 19,930 kWh |
$465 51 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,605 Cost: $8,500 |
- | - | - | - | - | - | - | - | - | - | $2,605 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
$2,605 - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF |
Savings: $2,549 Cost: $10,500 |
$2,207 | 75,909 | $2,178 | 237 | - | - | $(-1,836) | (-561,600) | - | - | - | - | - | - | - | - | - | - |
$2,207 75,909 kWh |
$2,178 237 kW-months/year |
- - MMBtu |
$(-1,836) (-561,600) Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,680 Cost: $1,216 |
- | - | - | - | $1,680 | 346 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,680 346 MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,347 Cost: $2,521 |
$774 | 26,671 | $573 | 62 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$774 26,671 kWh |
$573 62 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $1,100 Cost: - |
- | - | - | - | - | - | - | - | $1,100 | 833 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$1,100 833 gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $380 Cost: $500 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $380 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
$380 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $283,502 Cost: $230,437 |
$3,053 | 104,925 | $4,911 | 535 | $(-36,551) | (-7,569) | $(-1,836) | (-561,600) | $1,100 | 833 | $2,605 | - | $59,840 | - | $380 | - | $250,000 | - | $3,053 104,925 kWh |
$4,911 535 kW-months/year |
$(-36,551) (-7,569) MMBtu |
$(-1,836) (-561,600) Tgal |
$1,100 833 gal |
$2,605 - lb |
$59,840 - $ |
$380 - $ |
$250,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,786 Cost: - |
$1,128 | 38,687 | $1,818 | 198 | - | - | - | - | - | - | - | - | $(-160) | - | - | - | - | - | $1,128 38,687 kWh |
$1,818 198 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
$(-160) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Product |