Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1997
Principal Product Corrugated Packaging and Displays
NAICS n/a
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 205,000
Annual Production 640,000,000 Thousand Feet
Production Hrs. Annual 6,000
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $147,462 3,354,045 kWh $0.04
Electricity Demand $100,685 8,264 kW-months/year $12.18
Electricity Fees $6,367 - $ -
Natural Gas $207,605 54,740 MMBtu $3.79
TOTAL ENERGY COSTS $253,343
RECOMMENDED SAVINGS* $51,427 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $21,130
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb $ $
01: 4.126 INSTALL SENSORS TO DETECT DEFECTS Savings:
$27,000
Cost:
$90,000
- - - - - - - - - - $27,000 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
$27,000
-
$
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$9,925
Cost:
$10,000
- - $9,925 744 - - - - - - - - -
-
kWh
$9,925
744
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$7,517
Cost:
$500
- - - - $7,517 1,983 - - - - - - -
-
kWh
-
-
kW-months/year
$7,517
1,983
MMBtu
-
-
Tgal
-
-
lb
-
-
$
04: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER Savings:
$3,297
Cost:
$17,000
$(-2,510) (-33,705) - - - - $6,307 1,971,000 - - $(-500) - $(-2,510)
(-33,705)
kWh
-
-
kW-months/year
-
-
MMBtu
$6,307
1,971,000
Tgal
-
-
lb
$(-500)
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,088
Cost:
$2,144
$2,181 45,428 $907 68 - - - - - - - - $2,181
45,428
kWh
$907
68
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
$
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$600
Cost:
-
- - - - - - - - $600 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$600
-
lb
-
-
$
TOTAL RECOMMENDED Savings:
$51,427
Cost:
$119,644
$(-329) 11,723 $10,832 812 $7,517 1,983 $6,307 1,971,000 $600 - $26,500 - $(-329)
11,723
kWh
$10,832
812
kW-months/year
$7,517
1,983
MMBtu
$6,307
1,971,000
Tgal
$600
-
lb
$26,500
-
$
TOTAL IMPLEMENTED Savings:
$21,130
Cost:
$12,644
$2,181 45,428 $10,832 812 $7,517 1,983 - - $600 - - - $2,181
45,428
kWh
$10,832
812
kW-months/year
$7,517
1,983
MMBtu
-
-
Tgal
$600
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes