Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2000 |
Principal Product | Blow Molded and Injection Molded Housewares |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 220,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,600 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $455,875 | 10,305,100 | kWh | $0.04 |
Electricity Demand | $159,342 | 21,552 | kW-months/year | $7.39 |
Electricity Fees | $37,363 | - | $ | - |
Natural Gas | $25,704 | 6,999 | MMBtu | $3.67 |
TOTAL ENERGY COSTS | $719,040 | |||
RECOMMENDED SAVINGS* | $45,370 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,225 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF |
Savings: $11,648 Cost: $23,400 |
$8,165 | 176,436 | $4,260 | 551 | $(-777) | (-211,680) | - | - | - | - | - | - | - | - |
$8,165 176,436 kWh |
$4,260 551 kW-months/year |
$(-777) (-211,680) Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $850 Cost: $2,000 |
$558 | 12,016 | $292 | 38 | - | - | - | - | - | - | - | - | - | - |
$558 12,016 kWh |
$292 38 kW-months/year |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $11,276 Cost: $34,000 |
$9,096 | 196,366 | $2,180 | 282 | - | - | - | - | - | - | - | - | - | - |
$9,096 196,366 kWh |
$2,180 282 kW-months/year |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $6,099 Cost: $1,680 |
$4,968 | 107,268 | $1,131 | 146 | - | - | - | - | - | - | - | - | - | - |
$4,968 107,268 kWh |
$1,131 146 kW-months/year |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $5,144 Cost: - |
- | - | - | - | - | - | - | - | $5,144 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - gal |
$5,144 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,123 Cost: $7,200 |
$1,753 | 37,808 | $1,370 | 177 | - | - | - | - | - | - | - | - | - | - |
$1,753 37,808 kWh |
$1,370 177 kW-months/year |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,081 Cost: $6,484 |
$2,494 | 53,927 | $587 | 76 | - | - | - | - | - | - | - | - | - | - |
$2,494 53,927 kWh |
$587 76 kW-months/year |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $2,899 Cost: $5,700 |
- | - | - | - | - | - | $3,788 | 420 | $(-246) | (-141) | $(-370) | - | $(-273) | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$3,788 420 gal |
$(-246) (-141) lb |
$(-370) - $ |
$(-273) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,250 Cost: $1,400 |
- | - | $1,250 | 146 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$1,250 146 kW-months/year |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $45,370 Cost: $81,864 |
$27,034 | 583,821 | $11,070 | 1,416 | $(-777) | (-211,680) | $3,788 | 420 | $4,898 | (-141) | $(-370) | - | $(-273) | - | $27,034 583,821 kWh |
$11,070 1,416 kW-months/year |
$(-777) (-211,680) Tgal |
$3,788 420 gal |
$4,898 (-141) lb |
$(-370) - $ |
$(-273) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,225 Cost: $6,484 |
$2,494 | 53,927 | $587 | 76 | - | - | - | - | $5,144 | - | - | - | - | - | $2,494 53,927 kWh |
$587 76 kW-months/year |
- - Tgal |
- - gal |
$5,144 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material |