Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2001 |
Principal Product | Lithographic and Digital Printed Products |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 207 |
Plant Area (Sq.Ft.) | 164,458 |
Annual Production | 3,091,102 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $95,349 | 2,857,860 | kWh | $0.03 |
Electricity Demand | $89,915 | 8,980 | kW-months/year | $10.01 |
Electricity Fees | $10,732 | - | $ | - |
Natural Gas | $22,552 | 2,905 | MMBtu | $7.76 |
TOTAL ENERGY COSTS | $268,592 | |||
RECOMMENDED SAVINGS* | $63,099 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $19,395 Cost: $4,200 |
$807 | 24,170 | - | - | - | - | - | - | $(-1,296) | - | $1,884 | - | $18,000 | - |
$807 24,170 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$(-1,296) - $ |
$1,884 - $ |
$18,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $17,235 Cost: - |
- | - | - | - | - | - | $17,235 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$17,235 - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,721 Cost: $18,589 |
$4,355 | 130,401 | $2,366 | 236 | - | - | - | - | - | - | - | - | - | - |
$4,355 130,401 kWh |
$2,366 236 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $587 Cost: - |
$405 | 12,126 | $182 | 18 | - | - | - | - | - | - | - | - | - | - |
$405 12,126 kWh |
$182 18 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,659 Cost: $4,300 |
$1,144 | 34,263 | $515 | 51 | - | - | - | - | - | - | - | - | - | - |
$1,144 34,263 kWh |
$515 51 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,147 Cost: $2,563 |
$3,551 | 106,305 | $1,596 | 160 | - | - | - | - | - | - | - | - | - | - |
$3,551 106,305 kWh |
$1,596 160 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $4,050 Cost: $13,334 |
- | - | - | - | - | - | - | - | $4,050 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$4,050 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $3,106 Cost: $2,600 |
- | - | - | - | $3,106 | 400 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,106 400 MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,860 Cost: $1,920 |
$1,995 | 59,736 | $865 | 86 | - | - | - | - | - | - | - | - | - | - |
$1,995 59,736 kWh |
$865 86 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,339 Cost: $2,000 |
$1,208 | 36,175 | $1,131 | 113 | - | - | - | - | - | - | - | - | - | - |
$1,208 36,175 kWh |
$1,131 113 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,099 Cost: $49,506 |
$13,465 | 403,176 | $6,655 | 664 | $3,106 | 400 | $17,235 | - | $2,754 | - | $1,884 | - | $18,000 | - | $13,465 403,176 kWh |
$6,655 664 kW-months/year |
$3,106 400 MMBtu |
$17,235 - lb |
$2,754 - $ |
$1,884 - $ |
$18,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production |