Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2002 |
Principal Product | Architectural Glass |
NAICS | n/a |
SIC | 3231 - Products Of Purchased Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 44,000 |
Annual Production | 2,225 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $148,504 | 6,957,600 | kWh | $0.02 |
Electricity Demand | $141,439 | 14,306 | kW-months/year | $9.89 |
Electricity Fees | $55,568 | - | $ | - |
Natural Gas | $4,583 | 793 | MMBtu | $5.78 |
TOTAL ENERGY COSTS | $387,210 | |||
RECOMMENDED SAVINGS* | $32,431 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,615 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1193 CONVERT FROM BATCH OPERATION TO CONTINUOUS PROCESSING |
Savings: $14,150 Cost: $13,000 |
$(-1,200) | (-47,058) | - | - | - | - | $18,600 | 1,860,000 | $(-3,250) | - |
$(-1,200) (-47,058) kWh |
- - kW-months/year |
- - MMBtu |
$18,600 1,860,000 Tgal |
$(-3,250) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,467 Cost: $20,000 |
$9,467 | 420,744 | - | - | - | - | - | - | - | - |
$9,467 420,744 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $4,530 Cost: $1,000 |
$4,028 | 179,040 | $8,402 | 805 | $(-7,900) | (-1,366) | - | - | - | - |
$4,028 179,040 kWh |
$8,402 805 kW-months/year |
$(-7,900) (-1,366) MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $2,251 Cost: $1,100 |
- | - | - | - | $2,251 | 389 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,251 389 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,228 Cost: $4,000 |
$528 | 23,499 | $700 | 67 | - | - | - | - | - | - |
$528 23,499 kWh |
$700 67 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $519 Cost: $740 |
$321 | 14,301 | $198 | 19 | - | - | - | - | - | - |
$321 14,301 kWh |
$198 19 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $286 Cost: $800 |
- | - | - | - | $286 | 49 | - | - | - | - |
- - kWh |
- - kW-months/year |
$286 49 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $32,431 Cost: $40,640 |
$13,144 | 590,526 | $9,300 | 891 | $(-5,363) | (-928) | $18,600 | 1,860,000 | $(-3,250) | - | $13,144 590,526 kWh |
$9,300 891 kW-months/year |
$(-5,363) (-928) MMBtu |
$18,600 1,860,000 Tgal |
$(-3,250) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,615 Cost: $38,840 |
$9,116 | 411,486 | $898 | 86 | $2,251 | 389 | $18,600 | 1,860,000 | $(-3,250) | - | $9,116 411,486 kWh |
$898 86 kW-months/year |
$2,251 389 MMBtu |
$18,600 1,860,000 Tgal |
$(-3,250) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |