Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2003
Principal Product Printed Paper Catalogs and Magazines
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2759 - Commercial Printing, Nec
Sales $50,000,000-$100,000,000
# of Employees 550
Plant Area (Sq.Ft.) 600,000
Annual Production 4,800,000 Pounds
Production Hrs. Annual 7,200
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $748,789 27,674,500 kWh $0.03
Electricity Demand $560,916 59,354 kW-months/year $9.45
Electricity Fees $177,765 - $ -
Natural Gas $371,656 86,428 MMBtu $4.30
TOTAL ENERGY COSTS $2,037,694
RECOMMENDED SAVINGS* $232,697 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost
$ kWh $ kW-months/year $ Tgal $ $
01: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER Savings:
$137,202
Cost:
$84,000
$(-9,220) (-322,272) $(-5,360) (-537) $151,782 233,510,000 - - $(-9,220)
(-322,272)
kWh
$(-5,360)
(-537)
kW-months/year
$151,782
233,510,000
Tgal
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$64,456
Cost:
$144,540
$40,235 1,406,850 $24,221 2,427 - - - - $40,235
1,406,850
kWh
$24,221
2,427
kW-months/year
-
-
Tgal
-
-
$
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$10,369
Cost:
$22,000
$10,369 362,556 - - - - - - $10,369
362,556
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$9,686
Cost:
$5,767
$6,955 243,196 $2,731 274 - - - - $6,955
243,196
kWh
$2,731
274
kW-months/year
-
-
Tgal
-
-
$
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$5,580
Cost:
$12,500
- - $5,580 450 - - - - -
-
kWh
$5,580
450
kW-months/year
-
-
Tgal
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,604
Cost:
$7,821
$2,546 89,015 $1,058 106 - - - - $2,546
89,015
kWh
$1,058
106
kW-months/year
-
-
Tgal
-
-
$
07: 3.7137 REPLACE CLOTH RAGS WITH PAPER TOWELS Savings:
$1,800
Cost:
-
- - - - - - $1,800 - -
-
kWh
-
-
kW-months/year
-
-
Tgal
$1,800
-
$
TOTAL RECOMMENDED Savings:
$232,697
Cost:
$276,628
$50,885 1,779,345 $28,230 2,720 $151,782 233,510,000 $1,800 - $50,885
1,779,345
kWh
$28,230
2,720
kW-months/year
$151,782
233,510,000
Tgal
$1,800
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ $
Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost