Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2003
Principal Product Medical, Commercial, Lenticular signing
NAICS 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081 - Unsupported Plastics Film & Sheet
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 73,000
Annual Production 48,000,000 Pounds
Production Hrs. Annual 8,400
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $371,293 13,284,000 kWh $0.03
Electricity Demand $126,690 26,844 kW-months/year $4.72
Electricity Fees $151,620 - $ -
Natural Gas $17,289 2,310 MMBtu $7.48
TOTAL ENERGY COSTS $666,892
RECOMMENDED SAVINGS* $51,229 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$20,554
Cost:
$25,000
$15,949 544,320 $4,605 864 $15,949
544,320
kWh
$4,605
864
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$12,687
Cost:
$27,555
$10,070 343,686 $2,617 491 $10,070
343,686
kWh
$2,617
491
kW-months/year
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$8,675
Cost:
$2,014
$8,675 296,087 - - $8,675
296,087
kWh
-
-
kW-months/year
04: 4.4221 UTILIZE OUTSIDE CONTRACTING Savings:
$5,139
Cost:
$1,240
$4,293 146,507 $846 159 $4,293
146,507
kWh
$846
159
kW-months/year
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,517
Cost:
$1,605
$2,040 69,626 $477 90 $2,040
69,626
kWh
$477
90
kW-months/year
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$1,657
Cost:
$1,000
- - $1,657 252 -
-
kWh
$1,657
252
kW-months/year
TOTAL RECOMMENDED Savings:
$51,229
Cost:
$58,414
$41,027 1,400,226 $10,202 1,856 $41,027
1,400,226
kWh
$10,202
1,856
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand