Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2004 |
Principal Product | Corrugated Containers |
NAICS | 321920 - Wood Container and Pallet Manufacturing |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 270,000 |
Annual Production | 1,800,000 Thousand Feet |
Production Hrs. Annual | 7,200 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $269,615 | 9,270,200 | kWh | $0.03 |
Electricity Demand | $260,686 | 26,327 | kW-months/year | $9.90 |
Electricity Fees | $30,590 | - | $ | - |
Natural Gas | $587,442 | 108,787 | MMBtu | $5.40 |
TOTAL ENERGY COSTS | $1,164,613 | |||
RECOMMENDED SAVINGS* | $225,486 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $66,949 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $124,013 Cost: $650,000 |
$107,700 | 3,000,000 | $125,400 | 12,000 | $(-109,087) | (-20,201) | - | - |
$107,700 3,000,000 kWh |
$125,400 12,000 kW-months/year |
$(-109,087) (-20,201) MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $52,024 Cost: $103,390 |
$33,193 | 1,081,224 | $18,831 | 1,802 | - | - | - | - |
$33,193 1,081,224 kWh |
$18,831 1,802 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $673 Cost: $150 |
$673 | 21,954 | - | - | - | - | - | - |
$673 21,954 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $16,655 Cost: $13,500 |
- | - | - | - | $16,655 | 3,084 | - | - |
- - kWh |
- - kW-months/year |
$16,655 3,084 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $9,209 Cost: $16,500 |
- | - | - | - | $9,209 | 1,705 | - | - |
- - kWh |
- - kW-months/year |
$9,209 1,705 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $14,113 Cost: $10,500 |
$(-1,237) | (-40,284) | $(-702) | (-67) | - | - | $16,052 | 11,070,000 |
$(-1,237) (-40,284) kWh |
$(-702) (-67) kW-months/year |
- - MMBtu |
$16,052 11,070,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,043 Cost: $1,280 |
$3,094 | 100,773 | $1,949 | 187 | - | - | - | - |
$3,094 100,773 kWh |
$1,949 187 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $2,932 Cost: $360 |
- | - | - | - | $2,932 | 543 | - | - |
- - kWh |
- - kW-months/year |
$2,932 543 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $824 Cost: $1,600 |
$506 | 16,460 | $318 | 30 | - | - | - | - |
$506 16,460 kWh |
$318 30 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $225,486 Cost: $797,280 |
$143,929 | 4,180,127 | $145,796 | 13,952 | $(-80,291) | (-14,869) | $16,052 | 11,070,000 | $143,929 4,180,127 kWh |
$145,796 13,952 kW-months/year |
$(-80,291) (-14,869) MMBtu |
$16,052 11,070,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $66,949 Cost: $121,320 |
$36,960 | 1,203,951 | $20,780 | 1,989 | $9,209 | 1,705 | - | - | $36,960 1,203,951 kWh |
$20,780 1,989 kW-months/year |
$9,209 1,705 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |