Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2005 |
Principal Product | Laminated hard wood and plywood |
NAICS | 321999 - All Other Miscellaneous Wood Product Manufacturing |
SIC | 2499 - Wood Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 128 |
Plant Area (Sq.Ft.) | 348,720 |
Annual Production | 20,000 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,671 | 5,591,523 | kWh | $0.03 |
Electricity Demand | $168,996 | 21,213 | kW-months/year | $7.97 |
Electricity Fees | $17,380 | - | $ | - |
Natural Gas | $353,718 | 54,163 | MMBtu | $6.53 |
TOTAL ENERGY COSTS | $707,765 | |||
RECOMMENDED SAVINGS* | $67,526 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $20,843 Cost: $44,480 |
$13,617 | 432,320 | $7,226 | 846 | - | - |
$13,617 432,320 kWh |
$7,226 846 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,603 Cost: $3,060 |
$2,603 | 82,620 | - | - | - | - |
$2,603 82,620 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $14,141 Cost: $60,000 |
$1,936 | 61,440 | $1,064 | 126 | $11,141 | 1,895 |
$1,936 61,440 kWh |
$1,064 126 kW-months/year |
$11,141 1,895 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $13,391 Cost: $5,500 |
- | - | - | - | $13,391 | 2,051 |
- - kWh |
- - kW-months/year |
$13,391 2,051 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $2,240 Cost: $500 |
- | - | - | - | $2,240 | 343 |
- - kWh |
- - kW-months/year |
$2,240 343 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,787 Cost: $400 |
- | - | - | - | $1,787 | 274 |
- - kWh |
- - kW-months/year |
$1,787 274 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $4,880 Cost: $11,000 |
- | - | - | - | $4,880 | 747 |
- - kWh |
- - kW-months/year |
$4,880 747 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,010 Cost: - |
- | - | $3,010 | 360 | - | - |
- - kWh |
$3,010 360 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,689 Cost: - |
$1,234 | 39,165 | $1,455 | 174 | - | - |
$1,234 39,165 kWh |
$1,455 174 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,942 Cost: $1,054 |
$1,268 | 40,284 | $674 | 81 | - | - |
$1,268 40,284 kWh |
$674 81 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $67,526 Cost: $125,994 |
$20,658 | 655,829 | $13,429 | 1,587 | $33,439 | 5,310 | $20,658 655,829 kWh |
$13,429 1,587 kW-months/year |
$33,439 5,310 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |