Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2006
Principal Product Outboard engines
NAICS 333618 - Other Engine Equipment Manufacturing
SIC 3732 - Boat Building And Repairing
Sales $10,000,000-$50,000,000
# of Employees 125
Plant Area (Sq.Ft.) 122,000
Annual Production 2,600 Pieces
Production Hrs. Annual 2,250
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $94,756 2,492,999 kWh $0.04
Electricity Demand $63,561 8,269 kW-months/year $7.69
Natural Gas $71,521 7,422 MMBtu $9.64
TOTAL ENERGY COSTS $229,838
RECOMMENDED SAVINGS* $65,952 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $19,433
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$12,014
Cost:
-
$567 14,206 $157 20 $11,290 1,171 $567
14,206
kWh
$157
20
kW-months/year
$11,290
1,171
MMBtu
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$8,865
Cost:
$2,000
$4,811 120,583 $4,054 502 - - $4,811
120,583
kWh
$4,054
502
kW-months/year
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,944
Cost:
$23,000
$2,859 71,662 $3,085 382 - - $2,859
71,662
kWh
$3,085
382
kW-months/year
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$4,554
Cost:
$1,000
- - - - $4,554 472 -
-
kWh
-
-
kW-months/year
$4,554
472
MMBtu
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$32,657
Cost:
$3,352
$32,657 32,657 - - - - $32,657
32,657
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,135
Cost:
$640
$808 20,258 $327 40 - - $808
20,258
kWh
$327
40
kW-months/year
-
-
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$443
Cost:
$438
$190 4,759 $253 31 - - $190
4,759
kWh
$253
31
kW-months/year
-
-
MMBtu
08: 2.6232 INSTALL SET-BACK TIMERS Savings:
$340
Cost:
$100
- - $340 32 - - -
-
kWh
$340
32
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$65,952
Cost:
$30,530
$41,892 264,125 $8,216 1,007 $15,844 1,643 $41,892
264,125
kWh
$8,216
1,007
kW-months/year
$15,844
1,643
MMBtu
TOTAL IMPLEMENTED Savings:
$19,433
Cost:
$23,740
$4,234 106,126 $3,909 474 $11,290 1,171 $4,234
106,126
kWh
$3,909
474
kW-months/year
$11,290
1,171
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas