Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2006 |
Principal Product | polymer products |
NAICS | 326299 - All Other Rubber Product Manufacturing |
SIC | 2822 - Synthetic Rubber |
Sales | $10,000,000-$50,000,000 |
# of Employees | 275 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 250,000,000 Pieces |
Production Hrs. Annual | 8,616 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $226,259 | 6,437,500 | kWh | $0.04 |
Electricity Demand | $147,278 | 13,386 | kW-months/year | $11.00 |
Natural Gas | $33,871 | 3,386 | MMBtu | $10.00 |
TOTAL ENERGY COSTS | $407,408 | |||
RECOMMENDED SAVINGS* | $81,916 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $50,647 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $42,840 Cost: $1,800 |
- | - | - | - | - | - | $42,840 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$42,840 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $16,286 Cost: $2,450 |
- | - | - | - | - | - | $16,286 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$16,286 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $10,175 Cost: $1,000 |
- | - | - | - | $10,175 | 1,017 | - | - |
- - kWh |
- - kW-months/year |
$10,175 1,017 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,710 Cost: $5,940 |
$2,584 | 69,660 | $1,126 | 90 | - | - | - | - |
$2,584 69,660 kWh |
$1,126 90 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,821 Cost: $640 |
$1,901 | 51,234 | $920 | 79 | - | - | - | - |
$1,901 51,234 kWh |
$920 79 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,987 Cost: $450 |
$1,987 | 53,558 | - | - | - | - | - | - |
$1,987 53,558 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,529 Cost: - |
$1,192 | 32,138 | $337 | 50 | - | - | - | - |
$1,192 32,138 kWh |
$337 50 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,291 Cost: $400 |
- | - | - | - | $1,291 | 129 | - | - |
- - kWh |
- - kW-months/year |
$1,291 129 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,277 Cost: $200 |
- | - | $1,277 | 80 | - | - | - | - |
- - kWh |
$1,277 80 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,916 Cost: $12,880 |
$7,664 | 206,590 | $3,660 | 299 | $11,466 | 1,146 | $59,126 | - | $7,664 206,590 kWh |
$3,660 299 kW-months/year |
$11,466 1,146 MMBtu |
$59,126 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $50,647 Cost: $8,340 |
$3,776 | 101,798 | $2,740 | 220 | $1,291 | 129 | $42,840 | - | $3,776 101,798 kWh |
$2,740 220 kW-months/year |
$1,291 129 MMBtu |
$42,840 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |