Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2006
Principal Product Storage batteries
NAICS 335911 - Storage Battery Manufacturing
SIC 3691 - Storage Batteries
Sales <$500,000
# of Employees 350
Plant Area (Sq.Ft.) 350,000
Annual Production 750,000 Pieces
Production Hrs. Annual 6,000
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $785,301 26,186,204 kWh $0.03
Electricity Demand $539,188 54,744 kW-months/year $9.85
Natural Gas $1,022,453 109,635 MMBtu $9.33
TOTAL ENERGY COSTS $2,346,942
RECOMMENDED SAVINGS* $94,361 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $21,712
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$27,918
Cost:
$6,000
- - $27,918 2,700 - - -
-
kWh
$27,918
2,700
kW-months/year
-
-
MMBtu
02: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$25,159
Cost:
$4,500
- - - - $25,159 2,697 -
-
kWh
-
-
kW-months/year
$25,159
2,697
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$16,406
Cost:
$37,744
$9,904 314,424 $6,502 629 - - $9,904
314,424
kWh
$6,502
629
kW-months/year
-
-
MMBtu
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$9,970
Cost:
$14,000
$9,970 158,265 - - - - $9,970
158,265
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$5,306
Cost:
$500
- - - - $5,306 569 -
-
kWh
-
-
kW-months/year
$5,306
569
MMBtu
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$4,872
Cost:
$2,000
- - $4,872 389 - - -
-
kWh
$4,872
389
kW-months/year
-
-
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,730
Cost:
$5,500
$2,855 90,639 $1,875 181 - - $2,855
90,639
kWh
$1,875
181
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$94,361
Cost:
$70,244
$22,729 563,328 $41,167 3,899 $30,465 3,266 $22,729
563,328
kWh
$41,167
3,899
kW-months/year
$30,465
3,266
MMBtu
TOTAL IMPLEMENTED Savings:
$21,712
Cost:
$38,244
$9,904 314,424 $6,502 629 $5,306 569 $9,904
314,424
kWh
$6,502
629
kW-months/year
$5,306
569
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas