Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2006 |
Principal Product | Storage batteries |
NAICS | 335911 - Storage Battery Manufacturing |
SIC | 3691 - Storage Batteries |
Sales | <$500,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 750,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $785,301 | 26,186,204 | kWh | $0.03 |
Electricity Demand | $539,188 | 54,744 | kW-months/year | $9.85 |
Natural Gas | $1,022,453 | 109,635 | MMBtu | $9.33 |
TOTAL ENERGY COSTS | $2,346,942 | |||
RECOMMENDED SAVINGS* | $94,361 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,712 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $27,918 Cost: $6,000 |
- | - | $27,918 | 2,700 | - | - |
- - kWh |
$27,918 2,700 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED |
Savings: $25,159 Cost: $4,500 |
- | - | - | - | $25,159 | 2,697 |
- - kWh |
- - kW-months/year |
$25,159 2,697 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,406 Cost: $37,744 |
$9,904 | 314,424 | $6,502 | 629 | - | - |
$9,904 314,424 kWh |
$6,502 629 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $9,970 Cost: $14,000 |
$9,970 | 158,265 | - | - | - | - |
$9,970 158,265 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,306 Cost: $500 |
- | - | - | - | $5,306 | 569 |
- - kWh |
- - kW-months/year |
$5,306 569 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $4,872 Cost: $2,000 |
- | - | $4,872 | 389 | - | - |
- - kWh |
$4,872 389 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,730 Cost: $5,500 |
$2,855 | 90,639 | $1,875 | 181 | - | - |
$2,855 90,639 kWh |
$1,875 181 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $94,361 Cost: $70,244 |
$22,729 | 563,328 | $41,167 | 3,899 | $30,465 | 3,266 | $22,729 563,328 kWh |
$41,167 3,899 kW-months/year |
$30,465 3,266 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,712 Cost: $38,244 |
$9,904 | 314,424 | $6,502 | 629 | $5,306 | 569 | $9,904 314,424 kWh |
$6,502 629 kW-months/year |
$5,306 569 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |