Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2004 |
Principal Product | Printed Periodicals |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2759 - Commercial Printing, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 0 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $105,951 | 4,679,280 | kWh | $0.02 |
Electricity Demand | $145,368 | 14,102 | kW-months/year | $10.31 |
Natural Gas | $115,636 | 11,560 | MMBtu | $10.00 |
TOTAL ENERGY COSTS | $366,955 | |||
RECOMMENDED SAVINGS* | $55,914 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,493 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $11,512 Cost: $250 |
$8,188 | 361,808 | $3,324 | 580 | - | - | - | - |
$8,188 361,808 kWh |
$3,324 580 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $9,827 Cost: $5,000 |
- | - | $9,827 | 984 | - | - | - | - |
- - kWh |
$9,827 984 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $6,964 Cost: $86 |
$4,953 | 219,019 | $2,011 | 351 | - | - | - | - |
$4,953 219,019 kWh |
$2,011 351 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $4,877 Cost: $100,430 |
$2,692 | 118,964 | $2,185 | 31 | - | - | - | - |
$2,692 118,964 kWh |
$2,185 31 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $4,643 Cost: $1,290 |
$4,039 | 178,144 | $1,636 | 285 | - | - | $(-1,032) | - |
$4,039 178,144 kWh |
$1,636 285 kW-months/year |
- - MMBtu |
$(-1,032) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,222 Cost: $6,500 |
$1,591 | 70,320 | $2,631 | 459 | - | - | - | - |
$1,591 70,320 kWh |
$2,631 459 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,923 Cost: $86 |
$2,791 | 123,228 | $1,132 | 198 | - | - | - | - |
$2,791 123,228 kWh |
$1,132 198 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,561 Cost: $1,416 |
$2,533 | 111,926 | $1,028 | 179 | - | - | - | - |
$2,533 111,926 kWh |
$1,028 179 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,247 Cost: $2,020 |
- | - | - | - | $2,247 | 271 | - | - |
- - kWh |
- - kW-months/year |
$2,247 271 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $1,509 Cost: $1,338 |
$1,074 | 47,390 | $435 | 76 | - | - | - | - |
$1,074 47,390 kWh |
$435 76 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $764 Cost: - |
$544 | 24,052 | $220 | 39 | - | - | - | - |
$544 24,052 kWh |
$220 39 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $739 Cost: $295 |
$526 | 23,226 | $213 | 37 | - | - | - | - |
$526 23,226 kWh |
$213 37 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $633 Cost: $1,830 |
$524 | 23,296 | $109 | 19 | - | - | - | - |
$524 23,296 kWh |
$109 19 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $493 Cost: $860 |
$206 | 9,208 | $287 | 50 | - | - | - | - |
$206 9,208 kWh |
$287 50 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,914 Cost: $121,401 |
$29,661 | 1,310,581 | $25,038 | 3,288 | $2,247 | 271 | $(-1,032) | - | $29,661 1,310,581 kWh |
$25,038 3,288 kW-months/year |
$2,247 271 MMBtu |
$(-1,032) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,493 Cost: $5,818 |
$23,778 | 1,050,681 | $9,747 | 1,701 | - | - | $(-1,032) | - | $23,778 1,050,681 kWh |
$9,747 1,701 kW-months/year |
- - MMBtu |
$(-1,032) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |