Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
352
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0836 # 09 Y:2011 | 09 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,293 | $18,000 | Not Implemented |
UD0836 # 10 Y:2011 | 10 | 2011 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,389 | $10,000 | Not Implemented |
UD0785 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $199,480 | $23,400 | Not Implemented |
UD0785 # 02 Y:2008 | 02 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $66,859 | $121,500 | Implemented |
UD0785 # 03 Y:2008 | 03 | 2008 | REPLACE BOILER | $54,105 | $88,560 | Not Implemented |
UD0785 # 04 Y:2008 | 04 | 2008 | COVER OPEN TANKS | $13,767 | $55,000 | Not Implemented |
UD0785 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,828 | $98,908 | Implemented |
UD0785 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,484 | $640 | Not Implemented |
UD0785 # 07 Y:2008 | 07 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,742 | $5,924 | Implemented |
UD0785 # 08 Y:2008 | 08 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,606 | $0 | Not Implemented |
UD0785 # 09 Y:2008 | 09 | 2008 | OPTIMIZE PLANT POWER FACTOR | $3,317 | $4,500 | Not Implemented |
UD0785 # 10 Y:2008 | 10 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,512 | $1,000 | Implemented |
UD0785 # 11 Y:2008 | 11 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,180 | $0 | Not Implemented |
UD0763 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $36,135 | $5,242 | Implemented |
UD0763 # 02 Y:2007 | 02 | 2007 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $30,994 | $8,900 | Implemented |
UD0763 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,945 | $57,910 | Not Implemented |
UD0763 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,551 | $8,100 | Not Implemented |
UD0763 # 05 Y:2007 | 05 | 2007 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $2,275 | $0 | Not Implemented |
UD0763 # 06 Y:2007 | 06 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,835 | $3,670 | Not Implemented |
UD0720 # 01 Y:2005 | 01 | 2005 | USE MINIMUM STEAM OPERATING PRESSURE | $6,931 | $0 | Not Implemented |
UD0720 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,769 | $0 | Implemented |
UD0720 # 03 Y:2005 | 03 | 2005 | OPTIMIZE PLANT POWER FACTOR | $3,870 | $6,000 | Implemented |
UD0720 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,757 | $3,200 | Implemented |
UD0720 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,200 | $225 | Implemented |
UD0720 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,280 | $540 | Implemented |