Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
378
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0175 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $99,155 | $3,104 | Implemented |
SU0175 # 03 Y:2004 | 03 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $3,889 | $896 | Implemented |
SU0175 # 04 Y:2004 | 04 | 2004 | MINIMIZE WATER USAGE | $1,683 | $427 | Implemented |
SU0175 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,174 | $6,679 | Implemented |
SU0175 # 06 Y:2004 | 06 | 2004 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $9,764 | $8,647 | Implemented |
SU0175 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $510 | $468 | Implemented |
SU0175 # 08 Y:2004 | 08 | 2004 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $9,162 | $8,765 | Not Implemented |
SU0173 # 01 Y:2004 | 01 | 2004 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $13,244 | $0 | Not Implemented |
SU0173 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,991 | $0 | Not Implemented |
SU0173 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $919 | $57 | Implemented |
SU0173 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,102 | $117 | Not Implemented |
SU0173 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,444 | $4,290 | Not Implemented |
SU0173 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,001 | $9,164 | Implemented |
SU0173 # 07 Y:2004 | 07 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,555 | $48,418 | Not Implemented |
SU0164 # 01 Y:2003 | 01 | 2003 | INSTALL WIND POWERED ELECTRIC GENERATOR | $141,258 | $1,171,875 | Not Implemented |
SU0164 # 02 Y:2003 | 02 | 2003 | USE OPTIMUM THICKNESS INSULATION | $115,419 | $348,540 | Implemented |
SU0164 # 03 Y:2003 | 03 | 2003 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $30,000 | $76,518 | Not Implemented |
SU0164 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,096 | $55,580 | Implemented |
SU0164 # 05 Y:2003 | 05 | 2003 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $8,721 | $0 | Implemented |
SU0164 # 06 Y:2003 | 06 | 2003 | INSTALL WIND POWERED ELECTRIC GENERATOR | $7,910 | $10,000 | Not Implemented |
SU0164 # 07 Y:2003 | 07 | 2003 | REDESIGN PROCESS | $6,861 | $270 | Implemented |
SU0164 # 08 Y:2003 | 08 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,485 | $700 | Implemented |
SU0164 # 09 Y:2003 | 09 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,293 | $955 | Implemented |
SU0164 # 10 Y:2003 | 10 | 2003 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $847 | $1,744 | Implemented |
SU0164 # 11 Y:2003 | 11 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $723 | $608 | Implemented |