IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,480

matching recommendations
Reset
NAICS 311 Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0021 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $506 $1,243 Implemented
TT0021 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,508 $1,641 Implemented
TT0021 # 09 Y:2008 09 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $702 $263 Implemented
TT0021 # 10 Y:2008 10 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,633 $5,950 Not Implemented
MS0325 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,471 $24,719 Implemented
MS0325 # 02 Y:2008 02 2008 REPAIR AND ELIMINATE STEAM LEAKS $9,208 $156 Implemented
MS0325 # 03 Y:2008 03 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,992 $8,100 Not Implemented
MS0325 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,031 $7,308 Not Implemented
MS0325 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,772 $236 Not Implemented
MS0325 # 06 Y:2008 06 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $411 $1,800 Implemented
MS0325 # 07 Y:2008 07 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $318 $1,050 Implemented
SF0352 # 01 Y:2008 01 2008 USE PHOTOCELL CONTROLS $651 $664 Not Implemented
SF0352 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,436 $3,094 Not Implemented
SF0352 # 03 Y:2008 03 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,354 $1,767 Not Implemented
SF0352 # 04 Y:2008 04 2008 INSTALL OCCUPANCY SENSORS $405 $738 Not Implemented
SF0352 # 05 Y:2008 05 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $5,195 $21,950 Not Implemented
SF0352 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,658 $9,606 Not Implemented
AM0539 # 01 Y:2008 01 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $163,000 $105,000 Not Implemented
AM0539 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $30,400 $52,400 Not Implemented
AM0539 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,990 $0 Not Implemented
AM0539 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,140 $570 Not Implemented
AM0539 # 05 Y:2008 05 2008 OPTIMIZE PLANT POWER FACTOR $4,100 $15,230 Not Implemented
AM0539 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,830 $605 Not Implemented
BD0339 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $83 $35 Implemented
BD0339 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $221 $75 Not Implemented