Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
353
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0429 # 06 Y:2011 | 06 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,791 | $547 | Implemented |
WV0429 # 07 Y:2011 | 07 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,932 | $3,252 | Implemented |
WV0429 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,606 | $7,343 | Implemented |
WV0429 # 10 Y:2011 | 10 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $904 | $1,224 | Not Implemented |
WV0429 # 11 Y:2011 | 11 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $616 | $3,934 | Not Implemented |
WV0429 # 12 Y:2011 | 12 | 2011 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $562 | $256 | Implemented |
WV0429 # 13 Y:2011 | 13 | 2011 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $438 | $3,900 | Implemented |
LE0315 # 01 Y:2011 | 01 | 2011 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $404,827 | $2,200,000 | Not Implemented |
LE0315 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $48,359 | $25,500 | Not Implemented |
LE0315 # 03 Y:2011 | 03 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $25,842 | $2,500 | Not Implemented |
LE0315 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $22,464 | $250 | Implemented |
LE0315 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,864 | $50,000 | Implemented |
LE0315 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,689 | $40 | Not Implemented |
LE0315 # 07 Y:2011 | 07 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,281 | $20,000 | Not Implemented |
LE0315 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,370 | $2,000 | Not Implemented |
LE0315 # 09 Y:2011 | 09 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,370 | $249 | Implemented |
LE0312 # 01 Y:2011 | 01 | 2011 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $39,912 | $50,000 | Not Implemented |
LE0312 # 02 Y:2011 | 02 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $14,396 | $30,000 | Not Implemented |
LE0312 # 03 Y:2011 | 03 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $24,192 | $75,014 | Implemented |
LE0312 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $15,944 | $70 | Implemented |
LE0312 # 05 Y:2011 | 05 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,770 | $700 | Not Implemented |
LE0312 # 06 Y:2011 | 06 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $8,883 | $2,500 | Implemented |
LE0312 # 07 Y:2011 | 07 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $8,857 | $0 | Implemented |
LE0312 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,822 | $49,208 | Implemented |
LE0312 # 09 Y:2011 | 09 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,246 | $3,000 | Not Implemented |