Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsNAICS | 311119 | Other Animal Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0076 # 06 Y:2004 | 06 | 2004 | OPTIMIZE PLANT POWER FACTOR | $1,982 | $2,220 | Not Implemented |
UU0076 # 05 Y:2004 | 05 | 2004 | METER WASTE WATER | $5,360 | $1,500 | Not Implemented |
UU0076 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,300 | $4,824 | Not Implemented |
UU0076 # 03 Y:2004 | 03 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $30 | $0 | Not Implemented |
UU0076 # 02 Y:2004 | 02 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $24 | $40 | Not Implemented |
UU0076 # 01 Y:2004 | 01 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,600 | $2,000 | Not Implemented |
AM0472 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $6,580 | $590 | Implemented |
AM0472 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $6,640 | $720 | Implemented |
AM0472 # 03 Y:2004 | 03 | 2004 | USE SYNTHETIC LUBRICANT | $2,630 | $0 | Not Implemented |
AM0472 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $950 | $290 | Implemented |
AM0472 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,000 | $200 | Implemented |
AM0472 # 06 Y:2004 | 06 | 2004 | INSTALL SKYLIGHTS | $920 | $0 | Implemented |
AM0471 # 02 Y:2004 | 02 | 2004 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $6,640 | $4,600 | Implemented |
AM0471 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $7,600 | $930 | Implemented |
AM0471 # 03 Y:2004 | 03 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,020 | $270 | Implemented |
AM0471 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,450 | $400 | Implemented |
AM0471 # 05 Y:2004 | 05 | 2004 | USE SYNTHETIC LUBRICANT | $1,920 | $0 | Implemented |
AM0471 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $1,110 | $170 | Implemented |
AM0471 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230 | $630 | Implemented |
CO0545 # 05 Y:2004 | 05 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,290 | $250 | Not Implemented |
CO0545 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,170 | $420 | Implemented |
CO0545 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $355 | $800 | Implemented |
CO0545 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $5,800 | $1,760 | Implemented |
CO0545 # 01 Y:2004 | 01 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,950 | $1,500 | Implemented |
BD0256 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,641 | $14,500 | Implemented |