Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
638
matching recommendationsNAICS | 3112 | Grain and Oilseed Milling |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0232 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,717 | $2,000 | Implemented |
LL0232 # 08 Y:2005 | 08 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $5,876 | $60 | Implemented |
LL0232 # 09 Y:2005 | 09 | 2005 | USE PHOTOCELL CONTROLS | $2,101 | $700 | Implemented |
LL0232 # 10 Y:2005 | 10 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $756 | $0 | Not Implemented |
LL0232 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $597 | $0 | Not Implemented |
LL0232 # 12 Y:2005 | 12 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,185 | $1,120 | Implemented |
LL0232 # 13 Y:2005 | 13 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,350 | $3,010 | Implemented |
SF0311 # 17 Y:2005 | 17 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $19,680 | $12,330 | Implemented |
SF0311 # 16 Y:2005 | 16 | 2005 | ELIMINATE/REDUCE AN OPERATION | $1,600 | $0 | Not Implemented |
SF0311 # 15 Y:2005 | 15 | 2005 | MODIFY STARTUP/SHUTDOWN TIMES | $3,118 | $13,200 | Not Implemented |
SF0311 # 14 Y:2005 | 14 | 2005 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $22,029 | $46,851 | Not Implemented |
SF0311 # 13 Y:2005 | 13 | 2005 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $345 | $658 | Not Implemented |
SF0311 # 12 Y:2005 | 12 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,102 | $18,405 | Not Implemented |
SF0311 # 11 Y:2005 | 11 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $456 | $693 | Not Implemented |
SF0311 # 10 Y:2005 | 10 | 2005 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $3,402 | $5,030 | Not Implemented |
SF0311 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,804 | $2,332 | Not Implemented |
SF0311 # 08 Y:2005 | 08 | 2005 | USE PHOTOCELL CONTROLS | $412 | $480 | Not Implemented |
SF0311 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,363 | $6,375 | Implemented |
SF0311 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,803 | $2,959 | Not Implemented |
SF0311 # 05 Y:2005 | 05 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,622 | $504 | Not Implemented |
SF0311 # 04 Y:2005 | 04 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $24,768 | $2,108 | Implemented |
SF0311 # 03 Y:2005 | 03 | 2005 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,110 | $0 | Not Implemented |
SF0311 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,048 | $0 | Implemented |
SF0311 # 01 Y:2005 | 01 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $133,918 | $0 | Implemented |
LL0227 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $24,360 | $0 | Not Implemented |