Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

409

matching recommendations
Reset
NAICS 3113 Sugar and Confectionery Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0427 # 05 Y:2013 05 2013 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $196,098 $500,000 Not Implemented
UM0427 # 06 Y:2013 06 2013 INSTALL EFFICIENT RECTIFIERS $20,863 $12,000 Not Implemented
SF0429 # 01 Y:2013 01 2013 OPERATE BOILERS ON HIGH FIRE SETTING $18,109 $0 Not Implemented
SF0429 # 02 Y:2013 02 2013 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $578 $810 Implemented
SF0429 # 03 Y:2013 03 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,006 $16,020 Not Implemented
SF0429 # 04 Y:2013 04 2013 INSTALL OCCUPANCY SENSORS $14,210 $38,634 Not Implemented
SF0429 # 05 Y:2013 05 2013 USE COMPRESSOR AIR FILTERS $9,736 $36,817 Implemented
SF0429 # 06 Y:2013 06 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $919 $5,601 Implemented
SF0429 # 07 Y:2013 07 2013 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,991 $0 Not Implemented
SF0429 # 08 Y:2013 08 2013 RECOVER WASTE HEAT FROM EQUIPMENT $228,512 $0 Not Implemented
DL0101 # 01 Y:2013 01 2013 CLOSE OFF UNNEEDED STEAM LINES $5,097 $225 Not Implemented
DL0101 # 02 Y:2013 02 2013 USE OPTIMUM THICKNESS INSULATION $7,200 $432 Not Implemented
DL0101 # 03 Y:2013 03 2013 RECOVER WASTE HEAT FROM EQUIPMENT $51,000 $130,000 Not Implemented
DL0101 # 04 Y:2013 04 2013 REPLACE BOILER $16,867 $28,062 Not Implemented
DL0101 # 05 Y:2013 05 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $1,900 $3,500 Not Implemented
DL0101 # 06 Y:2013 06 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,700 $19,110 Not Implemented
DL0101 # 07 Y:2013 07 2013 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $7,100 $22,500 Not Implemented
DL0101 # 08 Y:2013 08 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $5,800 $0 Not Implemented
WV0462 # 01 Y:2013 01 2013 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $298,848 $180,000 Not Implemented
WV0462 # 02 Y:2013 02 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $167,190 $95,000 Not Implemented
WV0462 # 03 Y:2013 03 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $75,533 $77,000 Not Implemented
WV0462 # 04 Y:2013 04 2013 UPGRADE CONTROLS ON COMPRESSORS $65,843 $50,000 Not Implemented
WV0462 # 05 Y:2013 05 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $57,184 $0 Implemented
WV0462 # 06 Y:2013 06 2013 REPAIR OR REPLACE STEAM TRAPS $42,971 $6,850 Implemented
WV0462 # 07 Y:2013 07 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $25,992 $29,385 Implemented