Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
350
matching recommendationsNAICS | 3114 | Fruit and Vegetable Preserving and Specialty Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0327 # 10 Y:2006 | 10 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $666 | $2,370 | Not Implemented |
SF0327 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,873 | $33,600 | Not Implemented |
LM0113 # 01 Y:2006 | 01 | 2006 | CONDENSE OPERATION INTO ONE BUILDING | $333,734 | $180,000 | Not Implemented |
LM0113 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,650 | $16,170 | Not Implemented |
LM0113 # 03 Y:2006 | 03 | 2006 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $35,020 | $500 | Not Implemented |
SF0321 # 01 Y:2006 | 01 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,975 | $0 | Implemented |
SF0321 # 02 Y:2006 | 02 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,657 | $0 | Implemented |
SF0321 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,882 | $0 | Implemented |
SF0321 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $3,112 | $863 | Not Implemented |
SF0321 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,189 | $1,561 | Implemented |
SF0321 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,410 | $2,345 | Not Implemented |
SF0321 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $554 | $780 | Implemented |
SF0321 # 08 Y:2006 | 08 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,550 | $25,410 | Implemented |
SF0321 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,170 | $11,928 | Implemented |
LM0108 # 01 Y:2006 | 01 | 2006 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $42,160 | $64,000 | Not Implemented |
LM0108 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $9,822 | $0 | Not Implemented |
LM0108 # 03 Y:2006 | 03 | 2006 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $287,197 | $0 | Implemented |
LM0108 # 04 Y:2006 | 04 | 2006 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $16,460 | $0 | Implemented |
LM0108 # 05 Y:2006 | 05 | 2006 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $184,119 | $15,120 | Implemented |
SF0319 # 01 Y:2006 | 01 | 2006 | USE PHOTOCELL CONTROLS | $381 | $360 | Not Implemented |
SF0319 # 02 Y:2006 | 02 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $19,568 | $19,053 | Not Implemented |
SF0319 # 03 Y:2006 | 03 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $18,204 | $20,250 | Implemented |
SF0319 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,411 | $23,058 | Implemented |
SF0319 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,934 | $18,325 | Implemented |
SF0319 # 06 Y:2006 | 06 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,552 | $4,648 | Implemented |