IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,571

matching recommendations
Reset
NAICS 3114 Fruit and Vegetable Preserving and Specialty Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0355 # 13 Y:2004 13 2004 ADD AREA LIGHTING SWITCHES $1,045 $689 Not Implemented
SU0198 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,681 $0 Implemented
SU0198 # 02 Y:2004 02 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,671 $133 Implemented
SU0198 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,691 $736 Implemented
SU0198 # 04 Y:2004 04 2004 INSTALL OCCUPANCY SENSORS $925 $401 Not Implemented
SU0198 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,416 $883 Implemented
SU0198 # 06 Y:2004 06 2004 UPGRADE CONTROLS ON COMPRESSORS $25,497 $15,000 Implemented
OK0695 # 02 Y:2004 02 2004 RECOVER WASTE HEAT FROM EQUIPMENT $17,436 $17,500 Not Implemented
OK0695 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,386 $4,515 Not Implemented
OK0695 # 04 Y:2004 04 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $10,723 $21,750 Implemented
OK0695 # 05 Y:2004 05 2004 COMBINE UTILITY METERS $2,354 $2,546 Not Implemented
OK0695 # 06 Y:2004 06 2004 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $6,830 $0 Implemented
OK0695 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,073 $23,985 Not Implemented
OK0695 # 01 Y:2004 01 2004 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $35,493 $329,564 Not Implemented
OR0459 # 01 Y:2004 01 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,500 $10,500 Not Implemented
OR0459 # 02 Y:2004 02 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,750 $300 Implemented
OR0459 # 03 Y:2004 03 2004 UPGRADE CONTROLS ON COMPRESSORS $4,820 $36,600 Implemented
OR0459 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $34,250 $2,000 Implemented
OR0459 # 05 Y:2004 05 2004 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $5,330 $2,825 Implemented
OR0459 # 06 Y:2004 06 2004 OPTIMIZE PLANT POWER FACTOR $2,730 $5,130 Implemented
LE0193 # 01 Y:2004 01 2004 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $192,339 $50,000 n/a
LE0193 # 02 Y:2004 02 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $105,726 $58,053 n/a
LE0193 # 03 Y:2004 03 2004 REPAIR OR REPLACE STEAM TRAPS $17,227 $492 Implemented
LE0193 # 04 Y:2004 04 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,446 $2,000 Implemented
LE0193 # 05 Y:2004 05 2004 RECOVER WASTE HEAT FROM EQUIPMENT $13,252 $10,720 Not Implemented