IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,571

matching recommendations
Reset
NAICS 3114 Fruit and Vegetable Preserving and Specialty Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0260 # 07 Y:2003 07 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,720 $400 Implemented
WV0260 # 08 Y:2003 08 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $175 $0 Implemented
WV0260 # 09 Y:2003 09 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,444 $130 Implemented
WV0260 # 10 Y:2003 10 2003 REDUCE EXCESS STEAM BLEEDING $15,707 $60,000 Not Implemented
WV0260 # 11 Y:2003 11 2003 MINIMIZE WATER USAGE $26,493 $6,000 Not Implemented
WV0260 # 12 Y:2003 12 2003 REPAIR AND ELIMINATE STEAM LEAKS $411 $1,000 Implemented
WV0260 # 13 Y:2003 13 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $298 $40 Implemented
WV0260 # 14 Y:2003 14 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,307 $1,855 Not Implemented
SD0316 # 01 Y:2003 01 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,055 $3,750 Not Implemented
SD0316 # 02 Y:2003 02 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,922 $0 Implemented
SD0316 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,991 $300 Implemented
SD0316 # 04 Y:2003 04 2003 INSTALL SKYLIGHTS $872 $1,000 Not Implemented
SD0316 # 05 Y:2003 05 2003 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $47,600 $40,000 Not Implemented
SD0316 # 06 Y:2003 06 2003 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $11,188 $10,000 Not Implemented
SD0316 # 07 Y:2003 07 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $2,955 $9,800 Not Implemented
LM0050 # 01 Y:2003 01 2003 INSTALL SPECTRAL REFLECTORS / DELAMP $16,417 $270 Not Implemented
LM0050 # 02 Y:2003 02 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $606 $900 Not Implemented
LM0050 # 03 Y:2003 03 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,032 $342 Not Implemented
LM0050 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,993 $350 Implemented
LM0050 # 05 Y:2003 05 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,400 $280 Not Implemented
LM0050 # 06 Y:2003 06 2003 KEEP BOILER TUBES CLEAN $552 $1,000 Implemented
LM0050 # 07 Y:2003 07 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,896 $2,669 Implemented
LM0050 # 08 Y:2003 08 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $937 $2,580 Not Implemented
LM0050 # 09 Y:2003 09 2003 DEVELOP STANDARD OPERATING PROCEDURES $19,825 $6,026 Implemented
LM0050 # 10 Y:2003 10 2003 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $5,943 $1,000 Implemented