Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

441

matching recommendations
Reset
NAICS 311411 Frozen Fruit, Juice, and Vegetable Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0078 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $12,574 $2,300 Not Implemented
MI0078 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $3,925 $0 Not Implemented
MI0078 # 04 Y:2004 04 2004 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $6,702 $3,693 Not Implemented
MI0078 # 05 Y:2004 05 2004 $168,750 $6,904 Implemented
MI0078 # 06 Y:2004 06 2004 USE PHOTOCELL CONTROLS $2,151 $2,661 Not Implemented
MI0078 # 07 Y:2004 07 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,680 $2,670 Not Implemented
MI0078 # 08 Y:2004 08 2004 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $2,345 $239 Not Implemented
MI0078 # 09 Y:2004 09 2004 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $2,649 $15,260 Not Implemented
IA0330 # 01 Y:2003 01 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,889 $1,000 Not Implemented
IA0330 # 02 Y:2003 02 2003 DIRECT WARMEST AIR TO COMBUSTION INTAKE $916 $1,734 Not Implemented
IA0330 # 03 Y:2003 03 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $34,175 $36,000 Not Implemented
IA0330 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $487 $23 Implemented
IA0330 # 05 Y:2003 05 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,233 $220 Implemented
IA0330 # 06 Y:2003 06 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,040 $99 Implemented
IA0330 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,173 $7,342 Implemented
IA0330 # 08 Y:2003 08 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $866 $1,149 Implemented
IA0330 # 09 Y:2003 09 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,303 $0 Implemented
IA0330 # 10 Y:2003 10 2003 INSTALL OCCUPANCY SENSORS $684 $1,064 Implemented
OR0440 # 01 Y:2003 01 2003 $1,842,800 $348,000 Implemented
OR0440 # 02 Y:2003 02 2003 $15,000 $75 Not Implemented
OR0440 # 03 Y:2003 03 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $16,500 $5,130 Implemented
OR0440 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,500 $0 Not Implemented
OR0440 # 05 Y:2003 05 2003 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,600 $700 Implemented
OR0440 # 06 Y:2003 06 2003 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $765 $1,300 Not Implemented
OR0440 # 07 Y:2003 07 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $15,500 $38,200 Implemented