Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
444
matching recommendationsNAICS | 311411 | Frozen Fruit, Juice, and Vegetable Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0263 # 04 Y:2014 | 04 | 2014 | HEAT WATER WITH EXHAUST HEAT | $6,564 | $8,859 | Not Implemented |
MI0263 # 05 Y:2014 | 05 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,131 | $4,980 | Not Implemented |
MI0263 # 06 Y:2014 | 06 | 2014 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,052 | $560 | Implemented |
MI0263 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,377 | $10,770 | Not Implemented |
MI0263 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $1,643 | $497 | Implemented |
MI0263 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,472 | $1,660 | Implemented |
MI0263 # 10 Y:2014 | 10 | 2014 | USE OPTIMUM THICKNESS INSULATION | $1,375 | $360 | Implemented |
MI0263 # 11 Y:2014 | 11 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,317 | $80 | Implemented |
MI0263 # 12 Y:2014 | 12 | 2014 | INSULATE BARE EQUIPMENT | $708 | $280 | Not Implemented |
MI0263 # 13 Y:2014 | 13 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $409 | $173 | Implemented |
OR0626 # 01 Y:2014 | 01 | 2014 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $18,202 | $6,792 | Not Implemented |
OR0626 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,945 | $1,000 | Not Implemented |
OR0626 # 03 Y:2014 | 03 | 2014 | IMPROVE COMBUSTION CONTROL CAPABILITY | $11,422 | $7,219 | Not Implemented |
OR0626 # 04 Y:2014 | 04 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $7,138 | $5,500 | Not Implemented |
OR0626 # 05 Y:2014 | 05 | 2014 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $5,445 | $6,461 | Not Implemented |
OR0626 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $3,138 | $5,659 | Not Implemented |
OR0626 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,463 | $3,437 | Not Implemented |
OR0610 # 01 Y:2013 | 01 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $11,054 | $11,584 | Not Implemented |
OR0610 # 02 Y:2013 | 02 | 2013 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $8,287 | $11,998 | Not Implemented |
OR0610 # 03 Y:2013 | 03 | 2013 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $161,127 | $238,200 | Not Implemented |
OR0610 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,406 | $2,100 | Not Implemented |
OR0610 # 05 Y:2013 | 05 | 2013 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $64,511 | $85,275 | Implemented |
OR0610 # 06 Y:2013 | 06 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $8,077 | $26,477 | Not Implemented |
OR0610 # 07 Y:2013 | 07 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,621 | $24,248 | Not Implemented |
OR0610 # 08 Y:2013 | 08 | 2013 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $4,383 | $16,215 | Not Implemented |