IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

624

matching recommendations
Reset
NAICS 311421 Fruit and Vegetable Canning
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0405 # 08 Y:2012 08 2012 INSTALL OCCUPANCY SENSORS $3,761 $9,004 Implemented
SF0405 # 09 Y:2012 09 2012 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $112,997 $524,700 Not Implemented
SF0405 # 10 Y:2012 10 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,215 $62,332 Implemented
SF0405 # 11 Y:2012 11 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,005 $6,397 Not Implemented
MI0209 # 01 Y:2011 01 2011 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $4,297,734 $3,000,000 Implemented
MI0209 # 02 Y:2011 02 2011 HEAT WATER WITH EXHAUST HEAT $240,185 $30,000 Not Implemented
MI0209 # 03 Y:2011 03 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $192,436 $36,000 Not Implemented
MI0209 # 04 Y:2011 04 2011 REPLACE TREATED WATER WITH WELL / SURFACE WATER $132,137 $500,000 Implemented
MI0209 # 05 Y:2011 05 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $112,996 $1,950 Implemented
MI0209 # 06 Y:2011 06 2011 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $107,940 $330,568 Implemented
MI0209 # 07 Y:2011 07 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $32,204 $29,679 Implemented
MI0209 # 08 Y:2011 08 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $27,599 $1,320 Implemented
MI0209 # 09 Y:2011 09 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $13,681 $50 Implemented
MI0209 # 10 Y:2011 10 2011 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $22,382 $2,550 Not Implemented
MI0209 # 11 Y:2011 11 2011 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $10,779 $45,345 Not Implemented
MI0209 # 12 Y:2011 12 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $13,268 $3,200 Implemented
MI0209 # 13 Y:2011 13 2011 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $7,944 $2,000 Not Implemented
MI0209 # 14 Y:2011 14 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $5,235 $3,450 Implemented
MI0209 # 15 Y:2011 15 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $3,926 $3,450 Implemented
LE0312 # 01 Y:2011 01 2011 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $39,912 $50,000 Not Implemented
LE0312 # 02 Y:2011 02 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $14,396 $30,000 Not Implemented
LE0312 # 03 Y:2011 03 2011 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $24,192 $75,014 Implemented
LE0312 # 04 Y:2011 04 2011 INSTALL TIMERS AND/OR THERMOSTATS $15,944 $70 Implemented
LE0312 # 05 Y:2011 05 2011 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $1,770 $700 Not Implemented
LE0312 # 06 Y:2011 06 2011 USE RADIANT HEATER FOR SPOT HEATING $8,883 $2,500 Implemented