ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0094 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM THICKNESS INSULATION | $110 | $150 | Not Implemented |
UU0094 # 04 Y:2005 | 04 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,540 | $0 | Not Implemented |
UU0094 # 03 Y:2005 | 03 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $370 | $220 | Not Implemented |
UU0094 # 02 Y:2005 | 02 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,260 | $7,000 | Not Implemented |
UU0057 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,240 | $6,450 | Not Implemented |
UU0057 # 11 Y:2004 | 11 | 2004 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $25,500 | $192,450 | Not Implemented |
UU0057 # 10 Y:2004 | 10 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $398 | $20 | Implemented |
UU0057 # 09 Y:2004 | 09 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,920 | $0 | Implemented |
UU0057 # 08 Y:2004 | 08 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,320 | $809 | Not Implemented |
UU0057 # 07 Y:2004 | 07 | 2004 | INSTALL TURBULATORS | $1,680 | $1,747 | Not Implemented |
UU0057 # 06 Y:2004 | 06 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,110 | $2,000 | Not Implemented |
UU0057 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $792 | $100 | Implemented |
UU0057 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $829 | $20 | Not Implemented |
UU0057 # 03 Y:2004 | 03 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $279 | $129 | Not Implemented |
UU0057 # 05 Y:2004 | 05 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,493 | $25,000 | Not Implemented |
UU0041 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $1,080 | $950 | n/a |
UU0041 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,207 | $3,500 | n/a |
UU0041 # 01 Y:2003 | 01 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,352 | $2,000 | n/a |
UU0041 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $31,340 | $45,900 | n/a |
UU0041 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,860 | $0 | n/a |
UU0041 # 06 Y:2003 | 06 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $748 | $0 | n/a |
UU0040 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $57 | $55 | Not Implemented |
UU0040 # 05 Y:2003 | 05 | 2003 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1 | $0 | Not Implemented |
UU0040 # 04 Y:2003 | 04 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,285 | $0 | Not Implemented |
UU0040 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,957 | $0 | Not Implemented |