Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,413

matching recommendations
Reset
NAICS 3115 Dairy Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0259 # 13 Y:2004 13 2004 INSTALL SENSORS TO DETECT AND AVOID JAMS $15,723 $3,000 Implemented
GT0780 # 01 Y:2004 01 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,020 $11,903 Implemented
GT0780 # 02 Y:2004 02 2004 INSTALL TURBULATORS $11,482 $12,800 n/a
GT0780 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,654 $10,261 Implemented
GT0780 # 04 Y:2004 04 2004 UTILIZE A LESS EXPENSIVE COOLING METHOD $25,046 $92,125 Not Implemented
GT0780 # 05 Y:2004 05 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,772 $500 Implemented
GT0780 # 06 Y:2004 06 2004 COMBINE UTILITY METERS $23,320 $0 Not Implemented
GT0780 # 07 Y:2004 07 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,729 $1,209 Implemented
GT0780 # 08 Y:2004 08 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,512 $0 Not Implemented
GT0780 # 09 Y:2004 09 2004 REPAIR AND ELIMINATE STEAM LEAKS $7,453 $900 Implemented
GT0780 # 10 Y:2004 10 2004 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $12,344 $20,000 Not Implemented
GT0780 # 11 Y:2004 11 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,325 $1,600 Not Implemented
GT0780 # 12 Y:2004 12 2004 CONTROL PRESSURE ON STEAMER OPERATIONS $2,490 $800 Implemented
SU0184 # 01 Y:2004 01 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $9,982 $0 Implemented
SU0184 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,593 $1,000 Implemented
SU0184 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $3,478 $574 Implemented
SU0184 # 04 Y:2004 04 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,876 $2,584 Implemented
SU0184 # 05 Y:2004 05 2004 OPTIMIZE PLANT POWER FACTOR $5,619 $2,410 Implemented
SU0184 # 06 Y:2004 06 2004 USE SYNTHETIC LUBRICANT $2,480 $2,000 Implemented
SU0184 # 07 Y:2004 07 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,570 $26,324 Not Implemented
SU0184 # 08 Y:2004 08 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,125 $15,744 Implemented
AS0377 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $28,088 $120 Implemented
AS0377 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,107 $5,750 Implemented
AS0377 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,140 $20 Implemented
AS0377 # 04 Y:2004 04 2004 REDUCE VENTILATION AIR $1,236 $30 Implemented