Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsNAICS | 311514 | Dry, Condensed, and Evaporated Dairy Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0023 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,785 | $23,530 | Not Implemented |
TT0023 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,401 | $13,400 | Not Implemented |
TT0023 # 10 Y:2008 | 10 | 2008 | OPTIMIZE PLANT POWER FACTOR | $15,500 | $32,800 | Not Implemented |
TT0023 # 09 Y:2008 | 09 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $1,750 | $1,600 | Implemented |
TT0023 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,275 | $4,900 | Implemented |
TT0023 # 07 Y:2008 | 07 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,600 | $8,310 | Implemented |
TT0023 # 06 Y:2008 | 06 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $37,200 | $1,000 | Implemented |
TT0023 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $55,100 | $20,000 | Implemented |
TT0023 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,685 | $7,344 | Not Implemented |
TT0023 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,700 | $11,100 | Not Implemented |
UF0414 # 08 Y:2008 | 08 | 2008 | BURN A LESS EXPENSIVE GRADE OF FUEL | $217,282 | $100,000 | Not Implemented |
UF0414 # 07 Y:2008 | 07 | 2008 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $13,994 | $10,000 | Not Implemented |
UF0414 # 06 Y:2008 | 06 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,447 | $371 | Implemented |
UF0414 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $255 | $39 | Implemented |
UF0414 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,808 | $15,562 | Implemented |
UF0414 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $44,500 | $13,000 | Implemented |
UF0414 # 02 Y:2008 | 02 | 2008 | REDUCE DELIVERY SCHEDULES | $89,700 | $6,652 | Not Implemented |
UF0414 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,527 | $7,379 | Implemented |
UF0412 # 09 Y:2008 | 09 | 2008 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $1,822 | $10,480 | Implemented |
UF0412 # 10 Y:2008 | 10 | 2008 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $95,676 | $20,000 | Not Implemented |
UF0412 # 11 Y:2008 | 11 | 2008 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,359 | $4,246 | Implemented |
UF0412 # 08 Y:2008 | 08 | 2008 | INSTALL SET-BACK TIMERS | $15,103 | $4,916 | Implemented |
UF0412 # 07 Y:2008 | 07 | 2008 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,081 | $534 | Not Implemented |
UF0412 # 06 Y:2008 | 06 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $2,521 | $0 | Implemented |
UF0412 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $17,781 | $615 | Implemented |