Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
215
matching recommendationsNAICS | 31152 | Ice Cream and Frozen Dessert Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0275 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $1,197 | $4,096 | Not Implemented |
SF0275 # 08 Y:2004 | 08 | 2004 | USE PHOTOCELL CONTROLS | $613 | $2,971 | Not Implemented |
SF0275 # 09 Y:2004 | 09 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $30,592 | $34,814 | Not Implemented |
UU0041 # 01 Y:2003 | 01 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,352 | $2,000 | n/a |
UU0041 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,207 | $3,500 | n/a |
UU0041 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $1,080 | $950 | n/a |
UU0041 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $31,340 | $45,900 | n/a |
UU0041 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,860 | $0 | n/a |
UU0041 # 06 Y:2003 | 06 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $748 | $0 | n/a |
UU0040 # 01 Y:2003 | 01 | 2003 | OPTIMIZE PLANT POWER FACTOR | $1 | $0 | Not Implemented |
UU0040 # 02 Y:2003 | 02 | 2003 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $150 | $0 | Not Implemented |
UU0040 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,957 | $0 | Not Implemented |
UU0040 # 04 Y:2003 | 04 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,285 | $0 | Not Implemented |
UU0040 # 05 Y:2003 | 05 | 2003 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1 | $0 | Not Implemented |
UU0040 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $57 | $55 | Not Implemented |