Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,427
matching recommendationsNAICS | 31161 | Animal Slaughtering and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0396 # 08 Y:2006 | 08 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,234 | $1,702 | Implemented |
IA0396 # 09 Y:2006 | 09 | 2006 | USE MINIMUM STEAM OPERATING PRESSURE | $2,109 | $25 | Not Implemented |
OK0735 # 01 Y:2006 | 01 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $69,788 | $55,933 | Not Implemented |
OK0735 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,821 | $9,500 | Not Implemented |
OK0735 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $29,625 | $4,000 | Not Implemented |
OK0735 # 04 Y:2006 | 04 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,193 | $12,830 | Not Implemented |
OK0735 # 05 Y:2006 | 05 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,240 | $700 | Not Implemented |
LE0238 # 01 Y:2006 | 01 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,077,481 | $2,403,050 | Not Implemented |
LE0238 # 02 Y:2006 | 02 | 2006 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $902,617 | $540,000 | Not Implemented |
LE0238 # 03 Y:2006 | 03 | 2006 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $335,810 | $500 | Implemented |
LE0238 # 04 Y:2006 | 04 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $124,858 | $17,600 | Not Implemented |
LE0238 # 05 Y:2006 | 05 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,103 | $2,500 | Implemented |
LE0238 # 06 Y:2006 | 06 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,870 | $3,000 | Implemented |
LE0238 # 07 Y:2006 | 07 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,609 | $45,000 | Implemented |
LE0238 # 08 Y:2006 | 08 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,409 | $3,000 | Not Implemented |
LE0238 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,223 | $1,000 | Not Implemented |
LE0238 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,471 | $2,500 | Not Implemented |
LE0238 # 11 Y:2006 | 11 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,065 | $90 | Implemented |
UF0384 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,087 | $1,070 | Not Implemented |
UF0384 # 02 Y:2006 | 02 | 2006 | INSTALL OCCUPANCY SENSORS | $2,569 | $2,053 | Not Implemented |
UF0384 # 03 Y:2006 | 03 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $117 | $0 | Not Implemented |
UF0384 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,026 | $0 | Not Implemented |
UF0384 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,822 | $3,057 | Not Implemented |
UF0384 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $1,524 | $408 | Not Implemented |
UF0384 # 07 Y:2006 | 07 | 2006 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $2,857 | $575 | Not Implemented |