Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

219

matching recommendations
Reset
NAICS 311613 Rendering and Meat Byproduct Processing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0439 # 07 Y:2017 07 2017 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,395 $41,742 Implemented
AM0730 # 01 Y:2017 01 2017 UPGRADE CONTROLS ON COMPRESSORS $1,220 $20 Implemented
UA0138 # 01 Y:2015 01 2015 BURN A LESS EXPENSIVE GRADE OF FUEL $27,518 $0 Not Implemented
UA0138 # 02 Y:2015 02 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $671 $658 Not Implemented
UA0138 # 03 Y:2015 03 2015 OPTIMIZE PLANT POWER FACTOR $3,174 $3,210 Not Implemented
UA0138 # 04 Y:2015 04 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,270 $3,920 Not Implemented
UA0138 # 05 Y:2015 05 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $557 $186 Not Implemented
UA0131 # 01 Y:2014 01 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,273 $10,071 Not Implemented
UA0131 # 02 Y:2014 02 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $6,471 $2,508 Implemented
UA0131 # 03 Y:2014 03 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,501 $4,321 Not Implemented
UA0131 # 04 Y:2014 04 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $20,179 $127,000 Not Implemented
SU0356 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $609 $0 Not Implemented
SU0356 # 01 Y:2014 01 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,526 $0 Not Implemented
SU0356 # 03 Y:2014 03 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $128,704 $104,500 Not Implemented
SU0356 # 04 Y:2014 04 2014 ELIMINATE/REDUCE AN OPERATION $3,970 $2,341 Not Implemented
SU0356 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,282 $3,539 Not Implemented
SU0356 # 06 Y:2014 06 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,768 $1,900 Not Implemented
SU0356 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $637 $472 Not Implemented
SU0356 # 08 Y:2014 08 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $1,264 $951 Not Implemented
SU0356 # 09 Y:2014 09 2014 INSTALL OCCUPANCY SENSORS $577 $715 Not Implemented
UD0880 # 01 Y:2013 01 2013 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $37,553 $100,000 Not Implemented
UD0880 # 08 Y:2013 08 2013 REDUCE EXCESSIVE BOILER BLOWDOWN $35,463 $15,000 Implemented
UD0880 # 07 Y:2013 07 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,120 $1,000 Implemented
UD0880 # 09 Y:2013 09 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $25,120 $4,600 Implemented
UD0880 # 06 Y:2013 06 2013 UPGRADE CONTROLS ON COMPRESSORS $12,462 $0 Implemented