Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsNAICS | 3118 | Bakeries and Tortilla Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL2203 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,530 | $37,026 | Implemented |
UL2203 # 03 Y:2022 | 03 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,985 | $0 | Implemented |
UL2203 # 05 Y:2022 | 05 | 2022 | OPTIMIZE PLANT POWER FACTOR | $79,271 | $45,460 | Implemented |
UK1505 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,753 | $3,800 | Implemented |
UK1505 # 03 Y:2015 | 03 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,528 | $4,500 | Implemented |
UK1505 # 02 Y:2015 | 02 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,107 | $266 | Implemented |
UK1505 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,028 | $1,750 | Implemented |
UK1505 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,998 | $0 | Implemented |
UK1505 # 06 Y:2015 | 06 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $1,747 | $635 | Implemented |
UK1505 # 11 Y:2015 | 11 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $2,571 | $5,110 | Implemented |
UK1505 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $296 | $61 | Implemented |
UK1505 # 09 Y:2015 | 09 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,562 | $3,824 | Implemented |
UK1505 # 10 Y:2015 | 10 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $548 | $276 | Implemented |
UK1502 # 04 Y:2015 | 04 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,721 | $1,000 | Implemented |
UK1502 # 14 Y:2015 | 14 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $783 | $1,200 | Implemented |
UK1502 # 12 Y:2015 | 12 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $2,940 | $300 | Implemented |
UK1502 # 10 Y:2015 | 10 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,342 | $2,080 | Implemented |
UK1502 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,699 | $10,183 | Implemented |
UK1502 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,284 | $2,000 | Implemented |
UK1502 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,868 | $0 | Implemented |
UK1502 # 01 Y:2015 | 01 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $20,269 | $0 | Implemented |
UK1406 # 03 Y:2014 | 03 | 2014 | REPLACE BOILER | $18,647 | $49,610 | Implemented |
UK1406 # 02 Y:2014 | 02 | 2014 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $20,868 | $60,000 | Implemented |
UK1406 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $84,218 | $192,800 | Implemented |
UK1406 # 08 Y:2014 | 08 | 2014 | ADD AREA LIGHTING SWITCHES | $1,572 | $620 | Implemented |